Zint Barcode Generator and Zint Barcode Studio User Manual

Version 2.13.0.9

September 2024

1. Introduction

The Zint project aims to provide a complete cross-platform open source barcode generating solution. The package currently consists of a Qt-based GUI, a CLI command line executable and a library with an API to allow developers access to the capabilities of Zint. It is hoped that Zint provides a solution which is flexible enough for professional users while at the same time takes care of as much of the processing as possible to allow easy translation from input data to barcode image.

The library which forms the main component of the Zint project is currently able to encode data in over 50 barcode symbologies (types of barcode), for each of which it is possible to translate that data from either UTF-8 (Unicode) or a raw 8-bit data stream. The image can be rendered as a

Many options are available for setting the characteristics of the output image including the size and colour of the image, the amount of error correction used in the symbol and the orientation of the image.

1.1 Glossary

Some of the words and phrases used in this document are specific to barcoding, and so a brief explanation is given to help understanding:

symbol

A symbol is an image which encodes data according to one of the standards. This encompasses barcodes (linear symbols) as well as any of the other methods of representing data used in this program.

symbology

A method of encoding data to create a certain type of symbol.

linear

A linear or one-dimensional symbol is one which consists of bars and spaces, and is what most people associate with the term ‘barcode’. Examples include Code 128.

stacked

A stacked symbol consists of multiple linear symbols placed one above another and which together hold the message, usually alongside some error correction data. Examples include PDF417.

matrix

A matrix symbol is one based on a (usually square) grid of elements called modules. Examples include Data Matrix, but MaxiCode and DotCode are also considered matrix symbologies.

composite

A composite symbology is one which is made up of elements which are both linear and stacked. Those currently supported are made up of a linear ‘primary’ message above which is printed a stacked component based on the PDF417 symbology. These symbols also have a separator which separates the linear and the stacked components. The stacked component is most often referred to as the 2D (two-dimensional) component.

X-dimension

The X-dimension of a symbol is the size (usually the width) of the smallest element. For a linear symbology this is the width of the smallest bar. For matrix symbologies it is the width of the smallest module (usually a square). Barcode widths and heights are expressed in X-dimensions. Most linear symbologies can have their height varied whereas most matrix symbologies have a fixed width-to-height ratio where the height is determined by the width.

GS1 data

This is a structured way of representing information which consists of ‘chunks’ of data, each of which starts with an Application Identifier (AI). The AI identifies what type of information is being encoded.

Reader Initialisation (Programming)

Some symbologies allow a special character to be included which can be detected by the scanning equipment as signifying that the data is used to program or change settings in that equipment. This data is usually not passed on to the software which handles normal input data. This feature should only be used if you are familiar with the programming codes relevant to your scanner.

ECI

The Extended Channel Interpretations (ECI) mechanism allows for multi-language data to be encoded in symbols which would usually support only Latin-1 (ISO/IEC 8859-1 plus ASCII) characters. This can be useful, for example, if you need to encode Cyrillic characters, but should be used with caution as not all scanners support this method.

Two other concepts that are important are raster and vector.

raster

A low level bitmap representation of an image. BMP, GIF, PCX, PNG and TIF are raster file formats.

vector

A high level command- or data-based representation of an image. EMF, EPS and SVG are vector file formats. They require renderers to turn them into bitmaps.

2. Installing Zint

2.1 Linux

The easiest way to configure compilation is to take advantage of the CMake utilities. You will need to install CMake and libpng-dev first. For instance on apt systems:

sudo apt install git cmake build-essential libpng-dev

If you want to take advantage of Zint Barcode Studio you will also need to have Qt and its component "Desktop gcc 64-bit" installed, as well as mesa. For details see "README.linux" in the project root directory.

Once you have fulfilled these requirements unzip the source code tarball or clone the latest source

git clone https://git.code.sf.net/p/zint/code zint

and follow these steps in the top directory:

mkdir build
cd build
cmake ..
make
sudo make install

The CLI command line program can be accessed by typing

zint [options]

The GUI can be accessed by typing

zint-qt

To test that the installation has been successful a shell script is included in the "frontend" sub-directory. To run the test type

./test.sh

This should create numerous files in the sub-directory "frontend/test_sh_out" showing the many modes of operation which are available from Zint.

2.2 BSD

The latest Zint CLI, libzint library and GUI can be installed from the zint package on FreeBSD:

su
pkg install zint
exit

and on OpenBSD (where the GUI is in a separate zint-gui package):

su
pkg_add zint zint-gui
exit

To build from source (including for NetBSD) see "README.bsd" in the project root directory.

2.3 Microsoft Windows

For Microsoft Windows, Zint is distributed as a binary executable. Simply download the ZIP file, then right-click on the ZIP file and "Extract All". A new folder will be created within which are two binary files:

For fresh releases you will get a warning message from Microsoft Defender SmartScreen that this is an ‘unrecognised app’. This happens because Zint is a free and open-source software project with no advertising and hence no income, meaning we are not able to afford the $664 per year to have the application digitally signed by Microsoft.

To build Zint on Windows from source, see "win32/README".

2.4 Apple macOS

The latest Zint CLI and libzint can be installed using Homebrew.1 To install Homebrew input the following line into the macOS terminal

/bin/bash -c "$(curl -fsSL \
    https://raw.githubusercontent.com/Homebrew/install/HEAD/install.sh)"

Once Homebrew is installed use the following command to install the CLI and library

brew install zint

To build from source (and install the GUI) see "README.macos" in the project root directory.

2.5 Zint Tcl Backend

The Tcl backend in the "backend_tcl" sub-directory may be built using the provided TEA (Tcl Extension Architecture) build on Linux, Windows, macOS and Android. For Windows, an MSVC6 makefile is also available. See Annex C. Tcl Backend Binding for further details.

3. Using Zint Barcode Studio

Zint Barcode Studio is the graphical user interface for Zint. If you are starting from a command line interface you can start the GUI by typing

zint-qt

or on Windows

qtZint.exe

See the note in section 2.3 Microsoft Windows about Microsoft Defender SmartScreen.

Below is a brief guide to Zint Barcode Studio.

3.1 Main Window and Data Tab

Zint Barcode Studio on startup - main window with Data tab

This is the main window of Zint Barcode Studio. The top of the window shows a preview of the barcode that the current settings would create. These settings can be changed using the controls below. The text box in the "Data to Encode" groupbox on this first Data tab allows you to enter the data to be encoded. When you are happy with your settings you can use the "Save..." button to save the resulting image to a file.

The "Symbology" drop-down box gives access to all of the symbologies supported by Zint shown in alphabetical order. The text box to its right can filter the drop-down to only show matching symbologies. For instance typing "mail" will only show barcodes in the drop-down whose names contain the word "mail". Each word entered will match. So typing "mail post" will show barcodes whose names contain "mail" or "post" (or both).

The ellipsis button "..." to the right of the data text box invokes the Data Dialog - see 3.7 Data Dialog for details. The delete button delete next to it will clear the data text box and the ECI (Extended Channel Interpretations) drop-down if set.

To set the barcode as a Programming Initialisation symbol click the "Reader Init" checkbox. The "1234.." button to its right invokes the Sequence Dialog - see 3.8 Sequence Dialog. The zap button zap will clear all data and reset all settings for the barcode to defaults.

The "BMP" and "SVG" buttons at the bottom will copy the image to the clipboard in BMP format and SVG format respectively. Further copy-to-clipboard formats are available by clicking the "Menu" button, along with "CLI Equivalent...", "Save As...", "Factory Reset...", "Help", "About..." and "Quit" options. Most of the options are also available in a context menu by right-clicking the preview.

Zint Barcode Studio main menu (left) and context menu (right)

3.2 GS1 Composite Groupbox

Zint Barcode Studio encoding GS1 Composite data

In the middle of the Data tab is an area for creating composite symbologies which appears when the currently selected symbology is supported by the GS1 Composite symbology standard. GS1 data can then be entered with square brackets used to separate Application Identifier (AI) information from data as shown here. For details, see 6.3 GS1 Composite Symbols (ISO 24723).

3.3 Additional ECI/Data Segments Groupbox

Zint Barcode Studio encoding multiple segments

For symbologies that support ECIs (Extended Channel Interpretations) the middle of the Data tab is an area for entering additional data segments with their own ECIs. Up to 4 segments (including the main "Data to Encode" as segment 0) may be specified. See 4.16 Multiple Segments for details.

3.4 Symbology-specific Groupbox

Zint Barcode Studio showing Code 2 of 5 Interleaved settings

Many symbologies have extra options to change the content, format and appearance of the symbol generated. For those with few additional options (and no support for GS1 data or ECIs), the middle of the Data tab is an area for setting those options.

Here is shown the check digit options for an Interleaved Code 2 of 5 symbol (see 6.1.2.4 Interleaved Code 2 of 5 (ISO 16390)).

Symbologies with more than a few options (or support for GS1 data or ECIs) have a second Symbology-specific tab, shown next.

3.5 Symbology-specific Tab

Zint Barcode Studio showing Aztec Code options

A second tab appears for those symbologies with more than a few extra options.

Here is shown the options available for an Aztec Code symbol.

You can adjust its size or error correction level (see 6.6.8 Aztec Code (ISO 24778)), select how its data is to be treated (see 4.11 Input Modes), and set it as part of a Structured Append sequence of symbols (see 4.17 Structured Append).

3.6 Appearance Tab

Zint Barcode Studio showing Appearance tab options

The Appearance tab can be used to adjust the dimensions and other properties of the symbol.

The "Height" value affects the height of symbologies which do not have a fixed width-to-height ratio, i.e. those other than matrix symbologies. For such symbologies the "Automatic Height" checkbox will be enabled - uncheck this to manually adjust the height. The "Compliant Height" checkbox applies to symbologies that define a standard height - see 4.4 Adjusting Height.

Boundary bars can be added with the "Border Type" drop-down and their size adjusted with "Border Width", and whitespace can be adjusted both horizontally (first spinbox) and vertically (second spinbox), and also through the "Quiet Zones" checkbox if standard quiet zones are defined for the symbology.

The size of the saved image can be specified with "Printing Scale", and also by clicking the scaling icon to invoke the Set Printing Scale Dialog - see 4.9 Adjusting Image Size (X-dimension) for further details.

Adjusting the Print Size

The foreground and background colours can be set either using the text boxes which accept "RRGGBBAA" hexadecimal values and "C,M,Y,K" decimal percentage values, or by clicking the foreground eye eye and background eye eye buttons which invoke a colour picker.

The colour picker tool

(Note that to change the colours visually, the luminence slider, the long narrow column on the right, must be adjusted.) The color picker only deals in RGB(A), and will overwrite any CMYK values with RGB(A) values once "OK" is selected.

Back in the Appearance tab, the colours can be reset to black-on-white using the "Reset" button, and exchanged one for the other using the swap swap button next to it.

3.7 Data Dialog

Entering longer text input

Clicking on the ellipsis "..." button next to the "Data to Encode" text box in the Data tab opens a larger window which can be used to enter longer strings of text. You can also use this window to load data from a file.

The dialog is also available for additional ECI/Data segments by clicking the ellipsis button to the right of their data text boxes.

Note that if your data contains line feeds (LF) then the data will be split into separate lines in the dialog box. On saving the data back to the main text box any separate lines in the data will be escaped as '\n' and the "Parse Escapes" checkbox will be set. This only affects line feeds, not carriage returns (CR) or CR+LF pairs, and behaves the same on both Windows and Unix. (For details on escape sequences, see 4.1 Inputting Data.)

3.8 Sequence Dialog

Creating a sequence of barcode symbols

Clicking on the sequence button (labelled "1234..") in the Data tab opens the Sequence Dialog. This allows you to create multiple barcode images by entering a sequence of data inputs in the right hand panel. Sequences can also be automatically generated by entering parameters on the left hand side or by importing the data from a file. Zint will generate a separate barcode image for each line of text in the right hand panel. The format field determines the format of the automatically generated sequence where characters have the meanings as given below:

Table : Sequence Format Characters
Character Effect
$ Insert leading zeroes
# Insert leading spaces
* Insert leading asterisks
Any other character Interpreted literally

Once you’re happy with the Sequence Data, click the "Export..." button to bring up the Export Dialog, discussed next.

3.9 Export Dialog

Setting filenames for an exported sequence of barcode symbols

The Export Dialog invoked by pressing the "Export..." button in the Sequence Dialog sets the parameters for exporting the sequence of barcode images. Here you can set the output directory, the format of the output filenames and what their image type will be. Note that the symbology, colour and other formatting information are taken from the main window.

3.10 CLI Equivalent Dialog

CLI Equivalent Dialog

The CLI Equivalent Dialog can be invoked from the main menu or the context menu and displays the CLI command that will reproduce the barcode as currently configured in the GUI. Press the "Copy" button to copy the command to the clipboard, which can then be pasted into the command line.

4. Using the Command Line

This section describes how to encode data using the command line frontend (CLI) program. The examples given are for the Unix platform, but the same options are available for Windows - just remember to include the executable file extension if ".EXE" is not in your PATHEXT environment variable, i.e.:

zint.exe -d "This Text"

For compatibility with Windows the examples use double quotes to delimit data, though on Unix single quotes are generally preferable as they stop the shell from processing any characters such as backslash or dollar. A single quote itself is dealt with by terminating the single-quoted text, backslashing the single quote, and then continuing:

zint -d 'Text containing a single quote '\'' in the middle'

Some examples use backslash (\) to continue commands onto the next line. For Windows, use caret (^) instead.

Certain options that take values have short names as well as long ones, namely -b (--barcode), -d (--data), -i (--input), -o (--output) and -w (--whitesp). For these a space should be used to separate the short name from its value, to avoid ambiguity. For long names a space or an equals sign may be used. For instance:

zint -d "This Text"
zint --data="This Text"
zint --data "This Text"

The examples use a space separator for short option names, and an equals sign for long option names.

4.1 Inputting Data

The data to encode can be entered at the command line using the -d or --data option, for example

zint -d "This Text"

This will encode the text "This Text". Zint will use the default symbology, Code 128, and output to the default file "out.png" in the current directory. Alternatively, if libpng was not present when Zint was built, the default output file will be "out.gif".

The data input to the Zint CLI is assumed to be encoded in UTF-8 (Unicode) format (Zint will correctly handle UTF-8 data on Windows). If you are encoding characters beyond the 7-bit ASCII set using a scheme other than UTF-8 then you will need to set the appropriate input options as shown in 4.11 Input Modes below.

Non-printing characters can be entered on the command line using backslash (\) as an escape character in combination with the --esc switch. Permissible sequences are shown in the table below.

Table : Escape Sequences
Escape Sequence ASCII Equivalent Name Interpretation
\0 0x00 NUL Null character
\E 0x04 EOT End of Transmission
\a 0x07 BEL Bell
\b 0x08 BS Backspace
\t 0x09 HT Horizontal Tab
\n 0x0A LF Line Feed
\v 0x0B VT Vertical Tab
\f 0x0C FF Form Feed
\r 0x0D CR Carriage Return
\e 0x1B ESC Escape
\G 0x1D GS Group Separator
\R 0x1E RS Record Separator
\\ 0x5C \ Backslash
\dNNN NNN Any 8-bit character where NNN is decimal (000-255)
\oNNN 0oNNN Any 8-bit character where NNN is octal (000-377)
\xNN 0xNN Any 8-bit character where NN is hexadecimal (00-FF)
\uNNNN Any 16-bit Unicode BMP2 character where NNNN is hexadecimal (0000-FFFF)
\UNNNNNN Any 21-bit Unicode character where NNNNNN is hexadecimal (000000-10FFFF)

(Special escape sequences are available for Code 128 only to manually switch Code Sets and insert special FNC1 characters - see 6.1.10.1 Standard Code 128 (ISO 15417) for details.)

Input data can be read directly from file using the -i or --input switch as shown below. The input file is assumed to be UTF-8 formatted unless an alternative mode is selected. This option replaces the use of the -d switch.

zint -i somefile.txt

To read from stdin specify a single hyphen "-" as the input file.

Note that except when batch processing (see 4.12 Batch Processing below), the file (or stdin) should not end with a newline (LF on Unix, CR+LF on Windows) unless you want the newline to be encoded in the symbol.

4.2 Directing Output

Output can be directed to a file other than the default using the -o or --output switch. For example:

zint -o here.png -d "This Text"

This draws a Code 128 barcode in the file "here.png". If an Encapsulated PostScript file is needed simply append the filename with ".eps", and so on for the other supported file types:

zint -o there.eps -d "This Text"

The currently supported output file formats are shown in the following table.

Table : Output File Formats
Extension File format
bmp Windows Bitmap
emf Enhanced Metafile Format
eps Encapsulated PostScript
gif Graphics Interchange Format
pcx ZSoft Paintbrush image
png Portable Network Graphic
svg Scalable Vector Graphic
tif Tagged Image File Format
txt Text file (see 4.19 Other Options)

The filename can contain directories and sub-directories also, which will be created if they don’t already exist:

zint -o "dir/subdir/filename.eps" -d "This Text"

Note that on Windows, filenames are assumed to be UTF-8 encoded.

4.3 Selecting Barcode Type

Selecting which type of barcode you wish to produce (i.e. which symbology to use) can be done at the command line using the -b or --barcode switch followed by the appropriate integer value or name in the following table. For example to create a Data Matrix symbol you could use:

zint -b 71 -o datamatrix.png -d "Data to encode"

or

zint -b DATAMATRIX -o datamatrix.png -d "Data to encode"

Names are treated case-insensitively by the CLI, and the BARCODE_ prefix and any underscores are optional.

Table : Barcode Types (Symbologies)
Numeric Value Name3 Barcode Name
1 BARCODE_CODE11 Code 11
2* BARCODE_C25STANDARD Standard Code 2 of 5
3 BARCODE_C25INTER Interleaved 2 of 5
4 BARCODE_C25IATA Code 2 of 5 IATA
6 BARCODE_C25LOGIC Code 2 of 5 Data Logic
7 BARCODE_C25IND Code 2 of 5 Industrial
8 BARCODE_CODE39 Code 3 of 9 (Code 39)
9 BARCODE_EXCODE39 Extended Code 3 of 9 (Code 39+)
13 BARCODE_EANX EAN (EAN-2, EAN-5, EAN-8 and EAN-13)
14 BARCODE_EANX_CHK EAN + Check Digit
16* BARCODE_GS1_128 GS1-128 (UCC.EAN-128)
18 BARCODE_CODABAR Codabar
20 BARCODE_CODE128 Code 128 (automatic Code Set switching)
21 BARCODE_DPLEIT Deutsche Post Leitcode
22 BARCODE_DPIDENT Deutsche Post Identcode
23 BARCODE_CODE16K Code 16K
24 BARCODE_CODE49 Code 49
25 BARCODE_CODE93 Code 93
28 BARCODE_FLAT Flattermarken
29* BARCODE_DBAR_OMN GS1 DataBar Omnidirectional (including GS1 DataBar Truncated)
30* BARCODE_DBAR_LTD GS1 DataBar Limited
31* BARCODE_DBAR_EXP GS1 DataBar Expanded
32 BARCODE_TELEPEN Telepen Alpha
34 BARCODE_UPCA UPC-A
35 BARCODE_UPCA_CHK UPC-A + Check Digit
37 BARCODE_UPCE UPC-E
38 BARCODE_UPCE_CHK UPC-E + Check Digit
40 BARCODE_POSTNET POSTNET
47 BARCODE_MSI_PLESSEY MSI Plessey
49 BARCODE_FIM FIM
50 BARCODE_LOGMARS LOGMARS
51 BARCODE_PHARMA Pharmacode One-Track
52 BARCODE_PZN PZN
53 BARCODE_PHARMA_TWO Pharmacode Two-Track
54 BARCODE_CEPNET Brazilian CEPNet
55 BARCODE_PDF417 PDF417
56* BARCODE_PDF417COMP Compact PDF417 (Truncated PDF417)
57 BARCODE_MAXICODE MaxiCode
58 BARCODE_QRCODE QR Code
60 BARCODE_CODE128AB Code 128 (Suppress Code Set C)
63 BARCODE_AUSPOST Australia Post Standard Customer
66 BARCODE_AUSREPLY Australia Post Reply Paid
67 BARCODE_AUSROUTE Australia Post Routing
68 BARCODE_AUSDIRECT Australia Post Redirection
69 BARCODE_ISBNX ISBN (EAN-13 with verification stage)
70 BARCODE_RM4SCC Royal Mail 4-State Customer Code (RM4SCC)
71 BARCODE_DATAMATRIX Data Matrix (ECC200)
72 BARCODE_EAN14 EAN-14
73 BARCODE_VIN Vehicle Identification Number
74 BARCODE_CODABLOCKF Codablock-F
75 BARCODE_NVE18 NVE-18 (SSCC-18)
76 BARCODE_JAPANPOST Japanese Postal Code
77 BARCODE_KOREAPOST Korea Post
79* BARCODE_DBAR_STK GS1 DataBar Stacked
80* BARCODE_DBAR_OMNSTK GS1 DataBar Stacked Omnidirectional
81* BARCODE_DBAR_EXPSTK GS1 DataBar Expanded Stacked
82 BARCODE_PLANET PLANET
84 BARCODE_MICROPDF417 MicroPDF417
85* BARCODE_USPS_IMAIL USPS Intelligent Mail (OneCode)
86 BARCODE_PLESSEY UK Plessey
87 BARCODE_TELEPEN_NUM Telepen Numeric
89 BARCODE_ITF14 ITF-14
90 BARCODE_KIX Dutch Post KIX Code
92 BARCODE_AZTEC Aztec Code
93 BARCODE_DAFT DAFT Code
96 BARCODE_DPD DPD Code
97 BARCODE_MICROQR Micro QR Code
98 BARCODE_HIBC_128 HIBC Code 128
99 BARCODE_HIBC_39 HIBC Code 39
102 BARCODE_HIBC_DM HIBC Data Matrix ECC200
104 BARCODE_HIBC_QR HIBC QR Code
106 BARCODE_HIBC_PDF HIBC PDF417
108 BARCODE_HIBC_MICPDF HIBC MicroPDF417
110 BARCODE_HIBC_BLOCKF HIBC Codablock-F
112 BARCODE_HIBC_AZTEC HIBC Aztec Code
115 BARCODE_DOTCODE DotCode
116 BARCODE_HANXIN Han Xin (Chinese Sensible) Code
119 BARCODE_MAILMARK_2D Royal Mail 2D Mailmark (CMDM) (Data Matrix)
121 BARCODE_MAILMARK_4S Royal Mail 4-State Mailmark
128 BARCODE_AZRUNE Aztec Runes
129 BARCODE_CODE32 Code 32
130 BARCODE_EANX_CC GS1 Composite Symbol with EAN linear component
131* BARCODE_GS1_128_CC GS1 Composite Symbol with GS1-128 linear component
132* BARCODE_DBAR_OMN_CC GS1 Composite Symbol with GS1 DataBar Omnidirectional linear component
133* BARCODE_DBAR_LTD_CC GS1 Composite Symbol with GS1 DataBar Limited linear component
134* BARCODE_DBAR_EXP_CC GS1 Composite Symbol with GS1 DataBar Expanded linear component
135 BARCODE_UPCA_CC GS1 Composite Symbol with UPC-A linear component
136 BARCODE_UPCE_CC GS1 Composite Symbol with UPC-E linear component
137* BARCODE_DBAR_STK_CC GS1 Composite Symbol with GS1 DataBar Stacked component
138* BARCODE_DBAR_OMNSTK_CC GS1 Composite Symbol with GS1 DataBar Stacked Omnidirectional component
139* BARCODE_DBAR_EXPSTK_CC GS1 Composite Symbol with GS1 DataBar Expanded Stacked component
140 BARCODE_CHANNEL Channel Code
141 BARCODE_CODEONE Code One
142 BARCODE_GRIDMATRIX Grid Matrix
143 BARCODE_UPNQR UPNQR (Univerzalnega Plačilnega Naloga QR)
144 BARCODE_ULTRA Ultracode
145 BARCODE_RMQR Rectangular Micro QR Code (rMQR)
146 BARCODE_BC412 IBM BC412 (SEMI T1-95)

4.4 Adjusting Height

The height of a symbol (except those with a fixed width-to-height ratio) can be adjusted using the --height switch. For example:

zint --height=100 -d "This Text"

This specifies a symbol height of 100 times the X-dimension of the symbol.

The default height of most linear barcodes is 50.0X, but this can be changed for barcodes whose specifications give a standard height by using the switch --compliantheight. For instance

zint -b LOGMARS -d "This Text" --compliantheight

will produce a barcode of height 45.455X instead of the normal default of 50.0X. The flag also causes Zint to return a warning if a non-compliant height is given:

zint -b LOGMARS -d "This Text" --compliantheight --height=6.2
Warning 247: Height not compliant with standards

Another switch is --heightperrow, which can be useful for symbologies that have a variable number of linear rows, namely Codablock-F, Code 16K, Code 49, GS1 DataBar Expanded Stacked, MicroPDF417 and PDF417, as it changes the treatment of the height value from overall height to per-row height, allowing you to specify a consistent height for each linear row without having to know how many there are. For instance

zint -b PDF417 -d "This Text" --height=4 --heightperrow
zint -b PDF417 -d "This Text" --height=4 --heightperrow

will produce a barcode of height 32X, with each of the 8 rows 4X high.

4.5 Adjusting Whitespace

The amount of horizontal whitespace to the left and right of the generated barcode can be altered using the -w or --whitesp switch, in integral multiples of the X-dimension. For example:

zint -w 10 -d "This Text"

This specifies a whitespace width of 10 times the X-dimension of the symbol both to the left and to the right of the barcode.

The amount of vertical whitespace above and below the barcode can be altered using the --vwhitesp switch, in integral multiples of the X-dimension. For example for 3 times the X-dimension:

zint --vwhitesp=3 -d "This Text"

Note that the whitespace at the bottom appears below the text, if any.

Horizontal and vertical whitespace can of course be used together:

zint -b DATAMATRIX --whitesp=1 --vwhitesp=1 -d "This Text"

A --quietzones option is also available which adds quiet zones compliant with the symbology’s specification. This is in addition to any whitespace specified with the --whitesp or --vwhitesp switches.

Note that Codablock-F, Code 16K, Code 49, ITF-14, EAN-2 to EAN-13, ISBN, UPC-A and UPC-E have compliant quiet zones added by default. This can be disabled with the option --noquietzones.

4.6 Adding Boundary Bars and Boxes

Zint allows the symbol to be bound with ‘boundary bars’ (also known as ‘bearer bars’) using the option --bind. These bars help to prevent misreading of the symbol by corrupting a scan if the scanning beam strays off the top or bottom of the symbol. Zint can also put a border right around the symbol and its horizontal whitespace with the --box option.

The width of the boundary bars or box borders, in integral multiples of the X-dimension, must be specified using the --border switch. For example:

zint --box --border=10 -w 10 -d "This Text"
zint --border=10 --box -d "This Text" -w 10

gives a box with a width 10 times the X-dimension of the symbol. Note that when specifying a box, horizontal whitespace is usually required in order to create a quiet zone between the barcode and the sides of the box. To add a boundary bar to the top only use --bindtop.

For linear symbols, horizontal boundary bars appear tight against the barcode, inside any vertical whitespace (or text). For matrix symbols, however, where they are decorative rather than functional, boundary bars appear outside any whitespace.

zint -b QRCODE --border=1 --box -d "This Text" --quietzones

Codablock-F, Code 16K and Code 49 always have boundary bars, and default to particular horizontal whitespace values. Special considerations apply to ITF-14 and DPD - see 6.1.2.6 ITF-14 and 6.1.10.7 DPD Code for those symbologies.

4.7 Using Colour

The default colours of a symbol are a black symbol on a white background. Zint allows you to change this. The -r or --reverse switch allows the default colours to be inverted so that a white symbol is shown on a black background (known as “reflectance reversal” or “reversed reflectance”). For example the command

zint -r -d "This Text"

gives an inverted Code 128 symbol. This is not practical for most symbologies but white-on-black is allowed by the Aztec Code, Data Matrix, DotCode, Han Xin Code, Grid Matrix and QR Code symbology specifications.

For more specific needs the foreground (ink) and background (paper) colours can be specified using the --fg and --bg options followed by a number in "RRGGBB" hexadecimal notation (the same system used in HTML) or in "C,M,Y,K" decimal percentages format (the latter normally used with the --cmyk option - see below). For example the command

zint --fg=00FF00 -d "This Text"

alters the symbol to a bright green.

zint -d "This Text" --fg=00FF00

Zint also supports RGBA colour information for those output file formats which support alpha channels (currently only GIF, PCX, PNG, SVG and TIF, with GIF supporting either a background or foreground alpha but not both) in a "RRGGBBAA" format. For example:

zint --fg=00ff0055 -d "This Text"
zint -d "This Text" --fg=00FF0055

will produce a semi-transparent green foreground with a standard (white) background. Note that transparency is treated differently by raster and vector (SVG) output formats, as for vector output the background will “shine through” a transparent foreground. For instance

zint --bg=ff0000 --fg=ffffff00 ...

will give different results for PNG and SVG. Experimentation is advised!

In addition the --nobackground option will remove the background from all output formats except BMP.4

The --cmyk option is specific to output in Encapsulated PostScript (EPS) and TIF, and selects the CMYK colour space. Custom colours should then usually be given in the comma-separated "C,M,Y,K" format, where C, M, Y and K are expressed as decimal percentage values from 0 to 100. RGB values may still be used, in which case they will be converted formulaically to CMYK approximations.

4.8 Rotating the Symbol

The symbol can be rotated through four orientations using the --rotate option followed by the angle of rotation as shown below.

--rotate=0 (default)
--rotate=90
--rotate=180
--rotate=270
zint -d "This Text" --rotate=90

4.9 Adjusting Image Size (X-dimension)

The size of the image can be altered using the --scale option, which sets the X-dimension. The default scale is 1.0.

The scale is multiplied by 2 (with the exception of MaxiCode) before being applied to the X-dimension. For MaxiCode, it is multiplied by 10 for raster output, by 40 for EMF vector output, and by 2 otherwise (non-EMF vector output).

For non-MaxiCode raster output, the default scale of 1 results in an X-dimension of 2 pixels. For example for non-MaxiCode PNG images a scale of 5 will increase the X-dimension to 10 pixels. For MaxiCode, see 4.9.3 MaxiCode Raster Scaling below.

Scales for non-MaxiCode raster output should be given in increments of 0.5, i.e. 0.5, 1, 1.5, 2, 2.5, 3, 3.5, etc., to avoid the X-dimension varying across the symbol due to interpolation. 0.5 increments are also faster to render.

The minimum scale for non-MaxiCode raster output in non-dotty mode is 0.5, giving a minimum X-dimension of 1 pixel. For MaxiCode, it is 0.2. The minimum scale for raster output in dotty mode is 1 (see 4.15 Working with Dots). For raster output, text will not be printed for scales less than 1.

The minimum scale for vector output is 0.1, giving a minimum X-dimension of 0.2 (or for MaxiCode EMF output, 4). The maximum scale for both raster and vector is 200.

To summarize the more intricate details:

Table : Scaling Multipliers and Minima
MaxiCode? Output Multiplier Min. Scale (non-dotty) Min. Scale (dotty)
No Raster 2 0.5 1
No Vector 2 0.1 0.1
Yes Raster 10 0.2 N/A
Yes Vector (non-EMF) 2 0.1 N/A
Yes EMF 40 0.1 N/A

4.9.1 Scaling by X-dimension and Resolution

An alternative way to specify the scale, which takes the above details into account, is to specify measurable units using the --scalexdimdp option, which has the format

--scalexdimdp=X[,R]

where X is the X-dimension (in mm by default) and R is the resolution (in dpmm, dots per mm, by default). R is optional, and defaults to 12 dpmm, and X may be zero, in which case it uses a symbology-specific default. The units may be given in inches for X by appending "in", and in dpi (dots per inch) for R by appending "dpi". For example

zint -d "1234" --scalexdimdp=0.013in,300dpi

Explicit metric units may also be given by appending "mm" and "dpmm" as appropriate, and may be mixed with U.S. units:

zint -d "1234" --scalexdimdp=0.33mm,300dpi

4.9.2 Scaling Example

The GS1 General Specifications Section 5.2.6.6 ‘Symbol dimensions at nominal size’ gives an example of an EAN-13 barcode using the X-dimension of 0.33mm. To print that example as a PNG at 12 dpmm, the approximate equivalent of 300 dpi (dpi = dpmm * 25.4), specify a scale of 2, since 0.33 * 12 = 3.96 pixels, or 4 pixels rounding to the nearest pixel:

zint -b EANX -d "501234567890" --compliantheight --scale=2

This will result in output of 37.29mm x 25.56mm (WxH) at 12 dpmm. The same result can be achieved using the --scalexdimdp option with

zint -b EANX -d "501234567890" --compliantheight --scalexdimdp=0

as 0.33mm is the default X-dimension for EAN, and 12 dpmm the default resolution.

4.9.3 MaxiCode Raster Scaling

For MaxiCode symbols, which use hexagons, the scale for raster output is multiplied by 10 before being applied. The 0.5 increment recommended for normal raster output does not apply.

The minimum scale is 0.2, so the minimum X-dimension is 2 pixels. However scales below 0.5 are not recommended and may produce symbols that are not within the following size ranges.

MaxiCode symbols have fixed size ranges of 24.82mm to 27.93mm in width, and 23.71mm to 26.69mm in height, excluding quiet zones. The default X-dimension is 0.88mm. For example, to output at the default X-dimension at 600 dpi specify:

zint -b MAXICODE -d "MaxiCode (19 chars)" --scalexdimdp=0,600dpi

4.10 Human Readable Text (HRT) Options

For linear barcodes the text present in the output image can be removed by using the --notext option. Note also that for raster output text will not be printed for scales less than 1 (see 4.9 Adjusting Image Size (X-dimension)).

Text can be set to bold using the --bold option, or a smaller font can be substituted using the --small option. The --bold and --small options can be used together if required, but only for vector output.

zint --bold -d "This Text" --small

The gap between the barcode and the text can be adjusted using the --textgap option, where the gap is given in X-dimensions, and may be negative (minimum -5.0X, maximum 10.0X). The default gap is 1X. Note that a very small gap may cause accented texts to overlap with the barcode:

zint -d "Áccent" --textgap=0.1

For SVG output, the font preferred by Zint (monospaced “OCR-B” for EAN/UPC, “Arimo” - a proportional sans-serif font metrically compatible with “Arial” - for all others) can be embedded in the file for portability using the --embedfont option:

zint -d "Áccent" --embedfont

4.11 Input Modes

4.11.1 Unicode, Data, and GS1 Modes

By default all CLI input data is assumed to be encoded in UTF-8 format. Many barcode symbologies encode data using the Latin-1 (ISO/IEC 8859-1 plus ASCII) character set, so input is converted from UTF-8 to Latin-1 before being put in the symbol. In addition QR Code and its variants and Han Xin Code can by default encode Japanese (Kanji) or Chinese (Hanzi) characters which are also converted from UTF-8.

There are two exceptions to the Latin-1 default: Grid Matrix, whose default character set is GB 2312 (Chinese); and UPNQR, whose default character set is Latin-2 (ISO/IEC 8859-2 plus ASCII).

Table : Default Character Sets
Symbology Default character sets Alternate if input not Latin-1
Aztec Code Latin-1 None
Codablock-F Latin-1 None
Code 128 Latin-1 None
Code 16K Latin-1 None
Code One Latin-1 None
Data Matrix Latin-1 None
DotCode Latin-1 None
Grid Matrix GB 2312 (includes ASCII) N/A
Han Xin Latin-1 GB 18030 (includes ASCII)
MaxiCode Latin-1 None
MicroPDF417 Latin-1 None
Micro QR Code Latin-1 Shift JIS (includes ASCII5)
PDF417 Latin-1 None
QR Code Latin-1 Shift JIS (see above)
rMQR Latin-1 Shift JIS (see above)
Ultracode Latin-1 None
UPNQR Latin-2 N/A
All others ASCII N/A

If Zint encounters characters which can not be encoded using the default character encoding then it will take advantage of the ECI (Extended Channel Interpretations) mechanism to encode the data if the symbology supports it - see 4.11.2 Input Modes and ECI below.

GS1 data can be encoded in a number of symbologies. Application Identifiers (AIs) should be enclosed in [square brackets] followed by the data to be encoded (see 6.1.10.3 GS1-128). To encode GS1 data use the --gs1 option. GS1 mode is assumed (and doesn’t need to be set) for GS1-128, EAN-14, GS1 DataBar and GS1 Composite symbologies but is also available for Aztec Code, Code 16K, Code 49, Code One, Data Matrix, DotCode, QR Code and Ultracode.

Health Industry Barcode (HIBC) data may also be encoded in the symbologies Aztec Code, Codablock-F, Code 128, Code 39, Data Matrix, MicroPDF417, PDF417 and QR Code. Within this mode, the leading '+' and the check character are automatically added by Zint, conforming to HIBC Labeler Identification Code (HIBC LIC). For HIBC Provider Applications Standard (HIBC PAS), preface the data with a slash '/'.

The --binary option encodes the input data as given. Automatic code page translation to an ECI page is disabled, and no validation of the data’s encoding takes place. This may be used for raw binary or binary encrypted data. This switch plays together with the built-in ECI logic and examples may be found below.

The --fullmultibyte option uses the multibyte modes of QR Code, Micro QR Code, Rectangular Micro QR Code, Han Xin Code and Grid Matrix for non-ASCII data, maximizing density. This is achieved by using compression designed for Kanji/Hanzi characters; however some decoders take blocks which are encoded this way and interpret them as Kanji/Hanzi characters, thus causing data corruption. Symbols encoded with this option should be checked against decoders before they are used. The popular open-source ZXing decoder is known to exhibit this behaviour.

4.11.2 Input Modes and ECI

If your data contains characters that are not in the default character set, you may encode it using an ECI-aware symbology and an ECI value from Table : ECI Codes below. The ECI information is added to your code symbol as prefix data. The symbologies that support ECI are

Table : ECI-Aware Symbologies
Aztec Code Grid Matrix PDF417
Code One Han Xin Code QR Code
Data Matrix MaxiCode rMQR
DotCode MicroPDF417 Ultracode

Be aware that not all barcode readers support ECI mode, so this can sometimes lead to unreadable barcodes. If you are using characters beyond those supported by the default character set then you should check that the resulting barcode can be understood by your target barcode reader.

The ECI value may be specified with the --eci switch, followed by the value in the column "ECI Code" in the table below. The input data should be UTF-8 formatted. Zint automatically translates the data into the target encoding.

Table : ECI Codes
ECI Code Character Encoding Scheme (ISO/IEC 8859 schemes include ASCII)
3 ISO/IEC 8859-1 - Latin alphabet No. 1
4 ISO/IEC 8859-2 - Latin alphabet No. 2
5 ISO/IEC 8859-3 - Latin alphabet No. 3
6 ISO/IEC 8859-4 - Latin alphabet No. 4
7 ISO/IEC 8859-5 - Latin/Cyrillic alphabet
8 ISO/IEC 8859-6 - Latin/Arabic alphabet
9 ISO/IEC 8859-7 - Latin/Greek alphabet
10 ISO/IEC 8859-8 - Latin/Hebrew alphabet
11 ISO/IEC 8859-9 - Latin alphabet No. 5 (Turkish)
12 ISO/IEC 8859-10 - Latin alphabet No. 6 (Nordic)
13 ISO/IEC 8859-11 - Latin/Thai alphabet
15 ISO/IEC 8859-13 - Latin alphabet No. 7 (Baltic)
16 ISO/IEC 8859-14 - Latin alphabet No. 8 (Celtic)
17 ISO/IEC 8859-15 - Latin alphabet No. 9
18 ISO/IEC 8859-16 - Latin alphabet No. 10
20 Shift JIS (JIS X 0208 and JIS X 0201)
21 Windows 1250 - Latin 2 (Central Europe)
22 Windows 1251 - Cyrillic
23 Windows 1252 - Latin 1
24 Windows 1256 - Arabic
25 UTF-16BE (High order byte first)
26 UTF-8
27 ASCII (ISO/IEC 646 IRV)
28 Big5 (Taiwan) Chinese Character Set
29 GB 2312 (PRC) Chinese Character Set
30 Korean Character Set EUC-KR (KS X 1001:2002)
31 GBK Chinese Character Set
32 GB 18030 Chinese Character Set
33 UTF-16LE (Low order byte first)
34 UTF-32BE (High order bytes first)
35 UTF-32LE (Low order bytes first)
170 ISO/IEC 646 Invariant6
899 8-bit binary data

An ECI value of 0 does not encode any ECI information in the code symbol (unless the data contains non-default character set characters). In this case, the default character set applies (see Table : Default Character Sets above).

If no ECI is specified or a value of 0 is given, and the data does contain characters other than in the default character set, then Zint will automatically insert the appropriate single-byte ECI if possible (ECIs 3 to 24, excluding ECI 20), or failing that ECI 26 (UTF-8). A warning will be generated. This mechanism is not applied if the --binary option is given.

Multiple ECIs can be specified using the --segN options - see 4.16 Multiple Segments.

Note: the --eci=3 specification should only be used for special purposes. Using this parameter, the ECI information is explicitly added to the symbol. Nevertheless, for ECI Code 3, this is not usually required, as this is the default encoding for most barcodes, which is also active without any ECI information.

4.11.2.1 Input Modes and ECI Example 1

The Euro sign U+20AC can be encoded in ISO/IEC 8859-15. The Euro sign has the ISO/IEC 8859-15 codepoint hex "A4". It is encoded in UTF-8 as the hex sequence: "E2 82 AC". Those 3 bytes are contained in the file "utf8euro.txt". This command will generate the corresponding code:

zint -b 71 --scale=10 --eci=17 -i utf8euro.txt

This is equivalent to the commands (using the --esc switch):

zint -b 71 --scale=10 --eci=17 --esc -d "\xE2\x82\xAC"

zint -b 71 --scale=10 --eci=17 --esc -d "\u20AC"

and to the command:

zint -b 71 --scale=10 --eci=17 -d "€"
zint -b DATAMATRIX --eci=17 -d "€"

4.11.2.2 Input Modes and ECI Example 2

The Chinese character with the Unicode codepoint U+5E38 can be encoded in Big5 encoding. The Big5 representation of this character is the two hex bytes: "B1 60" (contained in the file "big5char.txt"). The generation command for Data Matrix is:

zint -b 71 --scale=10 --eci=28 --binary -i big5char.txt

This is equivalent to the command (using the --esc switch):

zint -b 71 --scale=10 --eci=28 --binary --esc -d "\xB1\x60"

and to the commands (no --binary switch so conversion occurs):

zint -b 71 --scale=10 --eci=28 --esc -d "\xE5\xB8\xB8"

zint -b 71 --scale=10 --eci=28 --esc -d "\u5E38"

zint -b 71 --scale=10 --eci=28 -d "常"
zint -b DATAMATRIX --eci=28 -d "\u5E38" --esc

4.11.2.3 Input Modes and ECI Example 3

Some decoders (in particular mobile app ones) for QR Code assume UTF-8 encoding by default and do not support ECI. In this case supply UTF-8 data and use the --binary switch so that the data will be encoded as UTF-8 without conversion:

zint -b 58 --binary -d "UTF-8 data"
zint -b QRCODE --binary -d "\xE2\x82\xAC\xE5\xB8\xB8" --esc

4.12 Batch Processing

Data can be batch processed by reading from a text file and producing a separate barcode image for each line of text in that file. To do this use the --batch switch together with -i to select the input file from which to read data. For example

zint -b EANX --batch -i ean13nos.txt

where "ean13nos.txt" contains a list of EAN-13 numbers (GTINs), each on its own line. Zint will automatically detect the end of a line of text (in either Unix or Windows formatted text files) and produce a symbol each time it finds this.

Input files should end with a line feed character - if this is not present then Zint will not encode the last line of text, and will warn you that there is a problem.

By default Zint will output numbered filenames starting with 00001.png, 00002.png etc. To change this behaviour specify the -o option using special characters in the output filename as shown in the table below:

Table : Batch Filename Formatting
Input Character Interpretation
~ Insert a number or 0
# Insert a number or space
@ Insert a number or * (or + on Windows)
Any other Insert literally

For instance

zint -b EANX --batch -i ean13nos.txt -o file~~~.svg

The following table shows some examples to clarify this method:

Table : Batch Filename Examples
Input Filenames Generated
-o file~~~.svg "file001.svg", "file002.svg", "file003.svg"
-o @@@@bar.png "***1.png", "***2.png", "***3.png" (except Windows)
-o @@@@bar.png "+++1.png", "+++2.png", "+++3.png" (on Windows)
-o my~~~bar.eps "my001bar.eps", "my002bar.eps", "my003bar.eps"
-o t#es~t~.png "t es0t1.png", "t es0t2.png", "t es0t3.png"

The special characters can span directories also, which is useful when creating a large number of barcodes:

Table : Batch Directory Examples
Input Filenames Generated
-o dir~/file~~~.svg "dir0/file001.svg", "dir0/file002.svg", …
, "dir0/file999.svg", "dir1/file000.svg", …

For an alternative method of naming output files see the --mirror option in 4.14 Automatic Filenames below.

4.13 Direct Output to stdout

The finished image files can be output directly to stdout for use as part of a pipe by using the --direct option. By default --direct will output data as a PNG image (or GIF image if libpng is not present), but this can be altered by supplementing the --direct option with a --filetype option followed by the suffix of the file type required. For example:

zint -b 84 --direct --filetype=pcx -d "Data to encode"

This command will output the symbol as a PCX file to stdout. For the supported output file formats see Table : Output File Formats.


CAUTION: Outputting binary files to the command shell without catching that data in a pipe can have unpredictable results. Use with care!


4.14 Automatic Filenames

The --mirror option instructs Zint to use the data to be encoded as an indicator of the filename to be used. This is particularly useful if you are processing batch data. For example the input data "1234567" will result in a file named "1234567.png".

There are restrictions, however, on what characters can be stored in a filename, so the filename may vary from the data if the data includes non-printable characters, for example, and may be shortened if the data input is long.

To set the output file format use the --filetype option as detailed above in 4.13 Direct Output to stdout. To output to a specific directory use the -o option giving the name of the directory (any filename will be ignored, unless --filetype is not specified, in which case the filename’s extension will be used).

4.15 Working with Dots

Matrix codes can be rendered as a series of dots or circles rather than the normal squares by using the --dotty option. This option is only available for matrix symbologies, and is automatically selected for DotCode. The size of the dots can be adjusted using the --dotsize option followed by the diameter of the dot, where that diameter is in X-dimensions. The minimum dot size is 0.01, the maximum is 20. The default size is 0.8.

The default and minimum scale for raster output in dotty mode is 1.

zint -b CODEONE -d "123456789012345678" --dotty --vers=9

4.16 Multiple Segments

If you need to specify different ECIs for different sections of the input data, the --seg1 to --seg9 options can be used. Each option is of the form --segN=ECI,data where ECI is the ECI code (see Table : ECI Codes) and data is the data to which this applies. This is in addition to the ECI and data specified using the --eci and -d options which must still be present and which in effect constitute segment 0. For instance

zint -b AZTEC_CODE --eci=9 -d "Κείμενο" --seg1=7,"Текст" --seg2=20,"文章"

specifies 3 segments: segment 0 with ECI 9 (Greek), segment 1 with ECI 7 (Cyrillic), and segment 2 with ECI 20 (Shift JIS). Segments must be consecutive.

Naturally the symbology must be ECI-aware (see Table : ECI-Aware Symbologies).

zint -b AZTEC --eci=9 -d "Κείμενο" --seg1=7,"Текст" --seg2=20,"文章"

ECIs of zero may be given, in which case Zint will automatically determine an ECI if necessary, as described in section 4.11.2 Input Modes and ECI.

Multiple segments are not currently supported for use with GS1 data.

4.17 Structured Append

Structured Append is a method of splitting data among several symbols so that they form a sequence that can be scanned and re-assembled in the correct order on reading, and is available for Aztec Code, Code One, Data Matrix, DotCode, Grid Matrix, MaxiCode, MicroPDF417, PDF417, QR Code and Ultracode.

The --structapp option marks a symbol as part of a Structured Append sequence, and has the format

--structapp=I,C[,ID]
zint -b DATAMATRIX -d "2nd of 3" --structapp="2,3,5006"

where I is the index (position) of the symbol in the Structured Append sequence, C is the count or total number of symbols in the sequence, and ID is an optional identifier (not available for Code One, DotCode or MaxiCode) that is the same for all symbols belonging to the same sequence. The index is 1-based and goes from 1 to count. Count must be 2 or more. See the individual symbologies for further details.

4.18 Help Options

There are three help options which give information about how to use the command line. The -h or --help option will display a list of all of the valid options available, and also gives the exact version of the software (the version by itself can be displayed with -v or --version).

The -t or --types option gives the table of symbologies along with the symbol ID numbers and names.

The -e or --ecinos option gives a list of the ECI codes.

4.19 Other Options

Zint can output a representation of the symbol data as a set of hexadecimal values if asked to output to a text file ("*.txt") or if given the option --filetype=txt. This can be used for test and diagnostic purposes.

Additional options are available which are specific to certain symbologies. These may, for example, control the amount of error correction data or the size of the symbol. These options are discussed in section 6. Types of Symbology of this guide.

5. Using the API

Zint has been written using the C language and has an API for use with C/C++ language programs. A Qt interface (see Annex B. Qt Backend QZint) is available in the "backend_qt" sub-directory, and a Tcl interface is available in the "backend_tcl" sub-directory (see Annex C. Tcl Backend Binding).

The libzint API has been designed to be very similar to that used by the GNU Barcode package. This allows easy migration from GNU Barcode to Zint. Zint, however, uses none of the same function names or option names as GNU Barcode. This allows you to use both packages in your application without conflict if you wish.

5.1 Creating and Deleting Symbols

The symbols manipulated by Zint are held in a zint_symbol structure defined in "zint.h". These symbol structures are created with the ZBarcode_Create() function and deleted using the ZBarcode_Delete() function. For example the following code creates and then deletes a symbol:

#include <zint.h>
#include <stdio.h>
int main()
{
    struct zint_symbol *my_symbol;
    my_symbol = ZBarcode_Create();
    if (my_symbol != NULL) {
        printf("Symbol successfully created!\n");
        ZBarcode_Delete(my_symbol);
    }
    return 0;
}

When compiling this code it will need to be linked with the libzint library using the -lzint option:

gcc -o simple simple.c -lzint

5.2 Encoding and Saving to File

To encode data in a barcode use the ZBarcode_Encode() function. To write the symbol to a file use the ZBarcode_Print() function. For example the following code takes a string from the command line and outputs a Code 128 symbol to a PNG file named "out.png" (or a GIF file "out.gif" if libpng is not present) in the current working directory:

#include <zint.h>
int main(int argc, char **argv)
{
    struct zint_symbol *my_symbol;
    my_symbol = ZBarcode_Create();
    ZBarcode_Encode(my_symbol, argv[1], 0);
    ZBarcode_Print(my_symbol, 0);
    ZBarcode_Delete(my_symbol);
    return 0;
}

This can also be done in one stage using the ZBarcode_Encode_and_Print() function as shown in the next example:

#include <zint.h>
int main(int argc, char **argv)
{
    struct zint_symbol *my_symbol;
    my_symbol = ZBarcode_Create();
    ZBarcode_Encode_and_Print(my_symbol, argv[1], 0, 0);
    ZBarcode_Delete(my_symbol);
    return 0;
}

Note that when using the API, the input data is assumed to be 8-bit binary unless the input_mode member of the zint_symbol structure is set - see 5.11 Setting the Input Mode for details.

5.3 Encoding and Printing Functions in Depth

The functions for encoding and printing barcodes are defined as:

int ZBarcode_Encode(struct zint_symbol *symbol,
      const unsigned char *source, int length);

int ZBarcode_Encode_File(struct zint_symbol *symbol,
      const char *filename);

int ZBarcode_Print(struct zint_symbol *symbol, int rotate_angle);

int ZBarcode_Encode_and_Print(struct zint_symbol *symbol,
      const unsigned char *source, int length, int rotate_angle);

int ZBarcode_Encode_File_and_Print(struct zint_symbol *symbol,
      const char *filename, int rotate_angle);

In these definitions length can be used to set the length of the input string. This allows the encoding of NUL (ASCII 0) characters in those symbologies which allow this. A value of 0 (or less than 0) will disable this usage and Zint will encode data up to the first NUL character in the input string, which must be present.

The rotate_angle value can be used to rotate the image when outputting. Valid values are 0, 90, 180 and 270.

The ZBarcode_Encode_File() and ZBarcode_Encode_File_and_Print() functions can be used to encode data read directly from a text file where the filename is given in the NUL-terminated filename string. The special filename "-" (single hyphen) can be used to read from stdin. Note that on Windows, filenames are assumed to be UTF-8 encoded.

If printing more than one barcode, the zint_symbol structure may be re-used by calling the ZBarcode_Clear() function after each barcode to free any output buffers allocated. The zint_symbol input members must be reset. To fully restore zint_symbol to its default state, call ZBarcode_Reset() instead.

5.4 Buffering Symbols in Memory (raster)

In addition to saving barcode images to file Zint allows you to access a representation of the resulting bitmap image in memory. The following functions allow you to do this:

int ZBarcode_Buffer(struct zint_symbol *symbol, int rotate_angle);

int ZBarcode_Encode_and_Buffer(struct zint_symbol *symbol,
      const unsigned char *source, int length, int rotate_angle);

int ZBarcode_Encode_File_and_Buffer(struct zint_symbol *symbol,
      const char *filename, int rotate_angle);

The arguments here are the same as above, and rotation and colour options can be used with the buffer functions in the same way as when saving to a file. The difference is that instead of saving the image to a file it is placed in a byte (unsigned char) array pointed to by the bitmap member, with bitmap_width set to the number of columns and bitmap_height set to the number of rows.

The RGB channels are split into 3 consecutive red, green, blue bytes per pixel, and there are bitmap_width pixels per row and bitmap_height rows, so the total size of the bitmap array is 3 * bitmap_width * bitmap_height.

If the background and/or foreground are RGBA then the byte array alphamap will also be set, with a single alpha value for each pixel. Its total size will be bitmap_width * bitmap_height.

The pixel data can be extracted from the array (or arrays) by the method shown in the example below, where render_rgb() and render_rgba() are assumed to be functions for drawing an RGB and RGBA pixel on the screen implemented by the client application:

int row, col, i = 0, j = 0;
int red, blue, green, alpha;

for (row = 0; row < my_symbol->bitmap_height; row++) {
     for (col = 0; col < my_symbol->bitmap_width; col++) {
          red = (int) my_symbol->bitmap[i];
          green = (int) my_symbol->bitmap[i + 1];
          blue = (int) my_symbol->bitmap[i + 2];
          if (my_symbol->alphamap) {
              alpha = (int) my_symbol->alphamap[j];
              render_rgba(row, col, red, green, blue, alpha);
              j++;
          } else {
              render_rgb(row, col, red, green, blue);
          }
          i += 3;
     }
}

Where speed is important, the buffer can be returned instead in a more compact intermediate form using the output option OUT_BUFFER_INTERMEDIATE. Here each byte is an ASCII value: '1' for foreground colour and '0' for background colour, except for Ultracode, which also uses colour codes: 'W' for white, 'C' for cyan, 'B' for blue, 'M' for magenta, 'R' for red, 'Y' for yellow, 'G' for green, and 'K' for black. Alpha values are not reported (alphamap will always be NULL). The loop for accessing the data is then:

int row, col, i = 0;

for (row = 0; row < my_symbol->bitmap_height; row++) {
     for (col = 0; col < my_symbol->bitmap_width; col++) {
          render_pixel(row, col, my_symbol->bitmap[i]);
          i++;
     }
}

5.5 Buffering Symbols in Memory (vector)

Symbols can also be saved to memory in a vector representation as well as a bitmap one. The following functions, exactly analogous to the ones above, allow you to do this:

int ZBarcode_Buffer_Vector(struct zint_symbol *symbol, int rotate_angle);

int ZBarcode_Encode_and_Buffer_Vector(struct zint_symbol *symbol,
      const unsigned char *source, int length, int rotate_angle);

int ZBarcode_Encode_File_and_Buffer_Vector(struct zint_symbol *symbol,
      const char *filename, int rotate_angle);

Here the vector member is set to point to a zint_vector header structure which contains pointers to lists of structures representing the various elements of the barcode: rectangles, hexagons, strings and circles. To draw the barcode, each of the element types is iterated in turn, and using the information stored is drawn by a rendering system. For instance, to draw a barcode using a rendering system with prepare_canvas(), draw_rect(), draw_hexagon(), draw_string(), and draw_circle() routines available:

struct zint_vector_rect *rect;
struct zint_vector_hexagon *hex;
struct zint_vector_string *string;
struct zint_vector_circle *circle;

prepare_canvas(my_symbol->vector->width, my_symbol->vector->height,
               my_symbol->scale, my_symbol->fgcolour, my_symbol->bgcolour,
               rotate_angle);

for (rect = my_symbol->vector->rectangles; rect; rect = rect->next) {
    draw_rect(rect->x, rect->y, rect->width, rect->height,
              rect->colour);
}
for (hex = my_symbol->vector->hexagons; hex; hex = hex->next) {
    draw_hexagon(hex->x, hex->y, hex->diameter, hex->rotation);
}
for (string = my_symbol->vector->strings; string; string = string->next) {
    draw_string(string->x, string->y, string->fsize,
                string->rotation, string->halign,
                string->text, string->length);
}
for (circle = my_symbol->vector->circles; circle; circle = circle->next) {
    draw_circle(circle->x, circle->y, circle->diameter, circle->width);
}

5.6 Buffering Symbols in Memory (memfile)

Symbols can also be stored as “in-memory” file buffers by giving the BARCODE_MEMORY_FILE option to the output_options member, which saves the print output to member memfile instead of to the output file outfile. The length of the buffer is given in memfile_size. For instance:

#include <zint.h>
#include <stdio.h>
#include <string.h>
int main(int argc, char **argv)
{
    struct zint_symbol *my_symbol;
    my_symbol = ZBarcode_Create();
    my_symbol->output_options |= BARCODE_MEMORY_FILE;
    /* Only the extension is used, to determine output format */
    strcpy(my_symbol->outfile, "mem.svg");
    ZBarcode_Encode_and_Print(my_symbol, argv[1], 0, 0);
    /* `my_symbol->memfile` now contains the SVG output */
    fwrite(my_symbol->memfile, 1, my_symbol->memfile_size, stdout);
    ZBarcode_Delete(my_symbol);
    return 0;
}

will print the SVG output to stdout (the file “mem.svg” is not created). This is particularly useful for the textual formats EPS and SVG,7 allowing the output to be manipulated and processed by the client.

5.7 Setting Options

So far our application is not very useful unless we plan to only make Code 128 symbols and we don’t mind that they only save to "out.png" (or to memory, as above). As with the CLI program, of course, these options can be altered. The way this is done is by altering the contents of the zint_symbol structure between the creation and encoding stages. The zint_symbol structure consists of the following members:

Table  : API Structure zint_symbol
Member Name Type Meaning Default Value
symbology integer Symbol to use - see 5.9 Specifying a Symbology. BARCODE_CODE128
height float Symbol height in X-dimensions, excluding fixed width-to-height symbols.8 Symbol dependent
scale float Scale factor for adjusting size of image (sets X-dimension). 1.0
whitespace_width integer Horizontal whitespace width in X-dimensions. 0
whitespace_height integer Vertical whitespace height in X-dimensions. 0
border_width integer Border width in X-dimensions. 0
output_options integer Set various output parameters - see 5.10 Adjusting Output Options. 0 (none)
fgcolour character string Foreground (ink) colour as RGB/RGBA hexadecimal string or "C,M,Y,K" decimal percentages string, with a terminating NUL. "000000"
bgcolour character string Background (paper) colour as RGB/RGBA hexadecimal string or "C,M,Y,K" decimal percentages string, with a terminating NUL. "ffffff"
fgcolor pointer Points to fgcolour allowing alternate spelling.
bgcolor pointer Points to bgcolour allowing alternate spelling.
outfile character string Contains the name of the file to output a resulting barcode symbol to. Must end in .png, .gif, .bmp, .emf, .eps, .pcx, .svg, .tif or .txt followed by a terminating NUL.9 "out.png"
primary character string Primary message data for more complex symbols, with a terminating NUL. "" (empty)
option_1 integer Symbol specific options. -1
option_2 integer Symbol specific options. 0
option_3 integer Symbol specific options. 0
show_hrt integer Set to 0 to hide Human Readable Text (HRT). 1
input_mode integer Set encoding of input data - see 5.11 Setting the Input Mode. DATA_MODE
eci integer Extended Channel Interpretation code. 0 (none)
dpmm float Resolution of output in dots per mm (BMP, EMF, PCX, PNG and TIF only). 0 (none)
dot_size float Diameter of dots used in dotty mode (in X-dimensions). 0.8
text_gap float Gap between barcode and text (HRT) in X-dimensions. 1.0
guard_descent float Height of guard bar descent (EAN/UPC only) in X-dimensions. 5.0
structapp Structured Append structure Mark a symbol as part of a sequence of symbols. count 0 (disabled)
debug integer Debugging flags. 0
warn_level integer Affects error/warning value returned by Zint API - see 5.8 Handling Errors. WARN_DEFAULT
text unsigned character string Human Readable Text, which usually consists of input data plus one more check digit. Uses UTF-8 formatting, with a terminating NUL. "" (empty) (output only)
rows integer Number of rows used by the symbol. (output only)
width integer Width of the generated symbol. (output only)
encoded_data array of unsigned character arrays Representation of the encoded data. (output only)
row_height array of floats Heights of each row. (output only)
errtxt character string Error message in the event that an error occurred, with a terminating NUL - see 5.8 Handling Errors. (output only)
bitmap pointer to unsigned character array Pointer to stored bitmap image - see 5.4 Buffering Symbols in Memory (raster). (output only)
bitmap_width integer Width of stored bitmap image (in pixels) - see bitmap member. (output only)
bitmap_height integer Height of stored bitmap image (in pixels) - see bitmap member. (output only)
alphamap pointer to unsigned character array Pointer to array representing alpha channel of stored bitmap image (or NULL if no alpha channel used) - see bitmap member. (output only)
vector pointer to vector structure Pointer to vector header containing pointers to vector elements - see 5.5 Buffering Symbols in Memory (vector). (output only)
memfile pointer to unsigned character array Pointer to in-memory file buffer if BARCODE_MEMORY_FILE set in output_options - see 5.6 Buffering Symbols in Memory (memfile). (output only)
memfile_size integer Length of in-memory file buffer. (output only)

To alter these values use the syntax shown in the example below. This code has the same result as the previous example except the output is now taller and plotted in green.

#include <zint.h>
#include <string.h>
int main(int argc, char **argv)
{
    struct zint_symbol *my_symbol;
    my_symbol = ZBarcode_Create();
    strcpy(my_symbol->fgcolour, "00ff00");
    my_symbol->height = 400.0f;
    ZBarcode_Encode_and_Print(my_symbol, argv[1], 0, 0);
    ZBarcode_Delete(my_symbol);
    return 0;
}

Note that background removal for all outputs except BMP can be achieved by setting the background alpha to "00" where the values for R, G and B will be ignored:

    strcpy(my_symbol->bgcolour, "55555500");

This is what the CLI option --nobackground does - see 4.7 Using Colour.

5.8 Handling Errors

If errors occur during encoding a non-zero integer value is passed back to the calling application. In addition the errtxt member is set to a message detailing the nature of the error. The errors generated by Zint are:

Table : API Warning and Error Return Values
Return Value Meaning
ZINT_WARN_HRT_TRUNCATED The Human Readable Text returned in text was truncated (maximum 199 bytes).
ZINT_WARN_INVALID_OPTION One of the values in zint_struct was set incorrectly but Zint has made a guess at what it should have been and generated a barcode accordingly.
ZINT_WARN_USES_ECI Zint has automatically inserted an ECI character. The symbol may not be readable with some readers.
ZINT_WARN_NONCOMPLIANT The symbol was created but is not compliant with certain standards set in its specification (e.g. height, GS1 AI data lengths).
ZINT_ERROR Marks the divide between warnings and errors. For return values greater than or equal to this no symbol (or only an incomplete symbol) is generated.
ZINT_ERROR_TOO_LONG The input data is too long or too short for the selected symbology. No symbol has been generated.
ZINT_ERROR_INVALID_DATA The data to be encoded includes characters which are not permitted by the selected symbology (e.g. alphabetic characters in an EAN symbol). No symbol has been generated.
ZINT_ERROR_INVALID_CHECK Data with an incorrect check digit has been entered. No symbol has been generated.
ZINT_ERROR_INVALID_OPTION One of the values in zint_struct was set incorrectly and Zint was unable (or unwilling) to guess what it should have been. No symbol has been generated.
ZINT_ERROR_ENCODING_PROBLEM A problem has occurred during encoding of the data. This should never happen. Please contact the developer if you encounter this error.
ZINT_ERROR_FILE_ACCESS Zint was unable to open the requested output file. This is usually a file permissions problem.
ZINT_ERROR_MEMORY Zint ran out of memory. This should only be a problem with legacy systems.
ZINT_ERROR_FILE_WRITE Zint failed to write all contents to the requested output file. This should only occur if the output device becomes full.
ZINT_ERROR_USES_ECI Returned if warn_level set to WARN_FAIL_ALL and ZINT_WARN_USES_ECI occurs.
ZINT_ERROR_NONCOMPLIANT Returned if warn_level set to WARN_FAIL_ALL and ZINT_WARN_NONCOMPLIANT occurs.
ZINT_ERROR_HRT_TRUNCATED Returned if warn_level set to WARN_FAIL_ALL and ZINT_WARN_HRT_TRUNCATED occurs.

To catch errors use an integer variable as shown in the code below:

#include <zint.h>
#include <stdio.h>
#include <string.h>
int main(int argc, char **argv)
{
    struct zint_symbol *my_symbol;
    int error;
    my_symbol = ZBarcode_Create();
    /* Set invalid foreground colour */
    strcpy(my_symbol->fgcolour, "nonsense");
    error = ZBarcode_Encode_and_Print(my_symbol, argv[1], 0, 0);
    if (error != 0) {
        /* Some warning or error occurred */
        printf("%s\n", my_symbol->errtxt);
        if (error >= ZINT_ERROR) {
            /* Stop now */
            ZBarcode_Delete(my_symbol);
            return 1;
        }
    }
    /* Otherwise carry on with the rest of the application */
    ZBarcode_Delete(my_symbol);
    return 0;
}

This code will exit with the appropriate message:

Error 881: Malformed foreground RGB colour 'nonsense' (hexadecimal only)

To treat all warnings as errors, set symbol->warn_level to WARN_FAIL_ALL.

5.9 Specifying a Symbology

Symbologies can be specified by number or by name as shown in the Table : Barcode Types (Symbologies). For example

symbol->symbology = BARCODE_LOGMARS;

means the same as

symbol->symbology = 50;

5.10 Adjusting Output Options

The output_options member can be used to adjust various aspects of the output file. To select more than one option from the table below simply OR them together when adjusting this value:

my_symbol->output_options |= BARCODE_BIND | READER_INIT;
Table  : API output_options Values
Value Effect
0 No options selected.
BARCODE_BIND_TOP Boundary bar above the symbol only.10
BARCODE_BIND Boundary bars above and below the symbol and between rows if stacking multiple symbols.11
BARCODE_BOX Add a box surrounding the symbol and whitespace.
BARCODE_STDOUT Output the file to stdout.
READER_INIT Create as a Reader Initialisation (Programming) symbol.
SMALL_TEXT Use a smaller font for the Human Readable Text.
BOLD_TEXT Embolden the Human Readable Text.
CMYK_COLOUR Select the CMYK colour space option for Encapsulated PostScript and TIF files.
BARCODE_DOTTY_MODE Plot a matrix symbol using dots rather than squares.
GS1_GS_SEPARATOR Use GS (Group Separator) instead of FNC1 as GS1 separator (Data Matrix only).
OUT_BUFFER_INTERMEDIATE Return the bitmap buffer as ASCII values instead of separate colour channels - see 5.4 Buffering Symbols in Memory (raster).
BARCODE_QUIET_ZONES Add compliant quiet zones (additional to any specified whitespace).12
BARCODE_NO_QUIET_ZONES Disable quiet zones, notably those with defaults.
COMPLIANT_HEIGHT Warn if height specified not compliant, or use standard height (if any) as default.
EANUPC_GUARD_WHITESPACE Add quiet zone indicators (“<” and/or “>”) to HRT whitespace (EAN/UPC).
EMBED_VECTOR_FONT Embed font in vector output - currently available for SVG output only.
BARCODE_MEMORY_FILE Write output to in-memory buffer symbol->memfile instead of to outfile file.

5.11 Setting the Input Mode

The way in which the input data is encoded can be set using the input_mode member. Valid values are shown in the table below.

Table  : API input_mode Values
Value Effect
DATA_MODE Uses full 8-bit range interpreted as binary data.
UNICODE_MODE Uses UTF-8 input.
GS1_MODE Encodes GS1 data using FNC1 characters.
The above are exclusive, the following optional and OR-ed.
ESCAPE_MODE Process input data for escape sequences.
GS1PARENS_MODE Parentheses (round brackets) used in GS1 data instead of square brackets to delimit Application Identifiers (parentheses must not otherwise occur in the data).
GS1NOCHECK_MODE Do not check GS1 data for validity, i.e. suppress checks for valid AIs and data lengths. Invalid characters (e.g. control characters, extended ASCII characters) are still checked for.
HEIGHTPERROW_MODE Interpret the height member as per-row rather than as overall height.
FAST_MODE Use faster if less optimal encodation or other shortcuts if available (affects DATAMATRIX, MICROPDF417, PDF417, QRCODE and UPNQR only).
EXTRA_ESCAPE_MODE Process special symbology-specific escape sequences (CODE128 only).

The default mode is DATA_MODE. (Note that this differs from the default for the CLI and GUI, which is UNICODE_MODE.)

DATA_MODE, UNICODE_MODE and GS1_MODE are mutually exclusive, whereas ESCAPE_MODE, GS1PARENS_MODE, GS1NOCHECK_MODE, HEIGHTPERROW_MODE, FAST_MODE and EXTRA_ESCAPE_MODE are optional. So, for example, you can set

my_symbol->input_mode = UNICODE_MODE | ESCAPE_MODE;

or

my_symbol->input_mode = GS1_MODE | GS1PARENS_MODE | GS1NOCHECK_MODE;

whereas

my_symbol->input_mode = DATA_MODE | GS1_MODE;

is not valid.

Permissible escape sequences (ESCAPE_MODE) are listed in Table : Escape Sequences, and the special Code 128-only EXTRA_ESCAPE_MODE escape sequences are given in 6.1.10.1 Standard Code 128 (ISO 15417). An example of GS1PARENS_MODE usage is given in section 6.1.10.3 GS1-128.

GS1NOCHECK_MODE is for use with legacy systems that have data that does not conform to the current GS1 standard. Printable ASCII input is still checked for, as is the validity of GS1 data specified without AIs (e.g. linear data for GS1 DataBar Omnidirectional/Limited/etc.). Also checked is GS1 DataBar Expanded and GS1 Composite input that is not in the GS1 encodable character set 82 (see GS1 General Specifications Figure 7.11.1 ‘GS1 AI encodable character set 82’), otherwise encodation would fail.

For HEIGHTPERROW_MODE, see --heightperrow in section 4.4 Adjusting Height. The height member should be set to the desired per-row value on input (it will be set to the overall height on output).

FAST_MODE causes a less optimal encodation scheme to be used for Data Matrix, MicroPDF417 and PDF417. For QR Code and UPNQR, it affects Zint’s automatic mask selection - see 6.6.3 QR Code (ISO 18004) for details.

5.12 Multiple Segments

For input data requiring multiple ECIs, the following functions may be used:

int ZBarcode_Encode_Segs(struct zint_symbol *symbol,
      const struct zint_seg segs[], const int seg_count);

int ZBarcode_Encode_Segs_and_Print(struct zint_symbol *symbol,
      const struct zint_seg segs[], const int seg_count, int rotate_angle);

int ZBarcode_Encode_Segs_and_Buffer(struct zint_symbol *symbol,
      const struct zint_seg segs[], const int seg_count, int rotate_angle);

int ZBarcode_Encode_Segs_and_Buffer_Vector(struct zint_symbol *symbol,
      const struct zint_seg segs[], const int seg_count, int rotate_angle);

These are direct analogues of the previously mentioned ZBarcode_Encode(), ZBarcode_Encode_and_Print(), ZBarcode_Encode_and_Buffer() and ZBarcode_Encode_and_Buffer_Vector() respectively, where instead of a pair consisting of "source, length", a pair consisting of "segs, seg_count" is given, with segs being an array of struct zint_seg segments and seg_count being the number of elements it contains. The zint_seg structure is of the form:

struct zint_seg {
    unsigned char *source; /* Data to encode */
    int length;            /* Length of `source`. If 0, `source` must be
                              NUL-terminated */
    int eci;               /* Extended Channel Interpretation */
};

The symbology must support ECIs (see Table : ECI-Aware Symbologies). For example:

#include <zint.h>
int main(int argc, char **argv)
{
    struct zint_seg segs[] = {
        { "Κείμενο", 0, 9 },
        { "Текст", 0, 7 },
        { "文章", 0, 20 }
    };
    struct zint_symbol *my_symbol;
    my_symbol = ZBarcode_Create();
    my_symbol->symbology = BARCODE_AZTEC;
    my_symbol->input_mode = UNICODE_MODE;
    ZBarcode_Encode_Segs(my_symbol, segs, 3);
    ZBarcode_Print(my_symbol, 0);
    ZBarcode_Delete(my_symbol);
    return 0;
}

A maximum of 256 segments may be specified. Use of multiple segments with GS1 data is not currently supported.

5.13 Scaling Helpers

To help with scaling the output, the following three function are available:

float ZBarcode_Default_Xdim(int symbol_id);

float ZBarcode_Scale_From_XdimDp(int symbol_id, float x_dim_mm, float dpmm,
        const char *filetype) {

float ZBarcode_XdimDP_From_Scale(int symbol_id, float scale,
        float x_dim_mm_or_dpmm, const char *filetype);

The first ZBarcode_Default_Xdim() returns the default X-dimension suggested by Zint for symbology symbol_id.

The second ZBarcode_Scale_From_XdimDp() returns the scale to use to output to a file of type filetype with X-dimension x_dim_mm at dpmm dots per mm. The given X-dimension must be non-zero and less than or equal to 10mm, however dpmm may be zero and defaults to 12 dpmm, and filetype may be NULL or empty in which case a GIF filetype is assumed. For raster output (BMP/GIF/PCX/PNG/TIF) the scale is rounded to half-integer increments.

For example:

/* Royal Mail 4-State Customer Code */
my_symbol->symbology = BARCODE_RM4SCC;
my_symbol->dpmm = 600.0f / 25.4f; /* 600 dpi */
my_symbol->scale = ZBarcode_Scale_From_XdimDp(
                        my_symbol->symbology,
                        ZBarcode_Default_Xdim(my_symbol->symbology),
                        my_symbol->dpmm, "PNG"); /* Returns 7.5 */

The third function ZBarcode_XdimDP_From_Scale() is the “reverse” of ZBarcode_Scale_From_XdimDp(), returning the X-dimension (in mm) or the dot density (in dpmm) given a scale scale. Both scale and x_dim_mm_or_dpmm must be non-zero. The returned value is bound to the maximum value of dpmm (1000), so must be further bound to 10 on return if the X-dimension is sought.

Note that the X-dimension to use is application dependent, and varies not only due to the symbology, resolution and filetype but also due to the type of scanner used, the intended scanning distance, and what media (“substrates”) the barcode appears on.

5.14 Verifying Symbology Availability

An additional function available in the API is:

int ZBarcode_ValidID(int symbol_id);

which allows you to check whether a given symbology is available, returning a non-zero value if so. For example:

if (ZBarcode_ValidID(BARCODE_PDF417) != 0) {
    printf("PDF417 available\n");
} else {
    printf("PDF417 not available\n");
}

Another function that may be useful is:

int ZBarcode_BarcodeName(int symbol_id, char name[32]);

which copies the name of a symbology into the supplied name buffer, which should be 32 characters in length. The name is NUL-terminated, and zero is returned on success. For instance:

char name[32];
if (ZBarcode_BarcodeName(BARCODE_PDF417, name) == 0) {
    printf("%s\n", name);
}

will print BARCODE_PDF417.

5.15 Checking Symbology Capabilities

It can be useful for frontend programs to know the capabilities of a symbology. This can be determined using another additional function:

unsigned int ZBarcode_Cap(int symbol_id, unsigned int cap_flag);

by OR-ing the flags below in the cap_flag argument and checking the return to see which are set.

Table : API Capability Flags
Value Meaning
ZINT_CAP_HRT Can the symbology print Human Readable Text?
ZINT_CAP_STACKABLE Is the symbology stackable?
ZINT_CAP_EANUPC13 Is the symbology EAN/UPC?
ZINT_CAP_COMPOSITE Does the symbology support composite data? (see 6.3 GS1 Composite Symbols (ISO 24723) below)
ZINT_CAP_ECI Does the symbology support Extended Channel Interpretations?
ZINT_CAP_GS1 Does the symbology support GS1 data?
ZINT_CAP_DOTTY Can the symbology be outputted as dots?
ZINT_CAP_QUIET_ZONES Does the symbology have default quiet zones?
ZINT_CAP_FIXED_RATIO Does the symbology have a fixed width-to-height (aspect) ratio?
ZINT_CAP_READER_INIT Does the symbology support Reader Initialisation?
ZINT_CAP_FULL_MULTIBYTE Is the ZINT_FULL_MULTIBYTE option applicable?
ZINT_CAP_MASK Is mask selection applicable?
ZINT_CAP_STRUCTAPP Does the symbology support Structured Append?
ZINT_CAP_COMPLIANT_HEIGHT Does the symbology have a compliant height defined?

For example:

unsigned int cap;
cap = ZBarcode_Cap(BARCODE_PDF417, ZINT_CAP_HRT | ZINT_CAP_ECI);
if (cap & ZINT_CAP_HRT) {
    printf("PDF417 supports HRT\n");
} else {
    printf("PDF417 does not support HRT\n");
}
if (cap & ZINT_CAP_ECI) {
    printf("PDF417 supports ECI\n");
} else {
    printf("PDF417 does not support ECI\n");
}

5.16 Zint Version

Whether the Zint library linked to was built with PNG support may be determined with:

int ZBarcode_NoPng();

which returns 1 if no PNG support is available, else zero.

Lastly, the version of the Zint library linked to is returned by:

int ZBarcode_Version();

The version parts are separated by hundreds. For instance, version "2.9.1" is returned as "20901".

6. Types of Symbology

6.1 One-Dimensional Symbols

One-dimensional or linear symbols are what most people associate with the term barcode. They consist of a number of bars and a number of spaces of differing widths.

6.1.1 Code 11

zint -b CODE11 -d "9212320967"

Developed by Intermec in 1977, Code 11 is similar to Code 2 of 5 Matrix and is primarily used in telecommunications. The symbol can encode data consisting of the digits 0-9 and the dash character (-) up to a maximum of 140 characters. Two modulo-11 check digits are added by default. To add just one check digit, set --vers=1 (API option_2 = 1). To add no check digits, set --vers=2 (API option_2 = 2).

6.1.2 Code 2 of 5

Code 2 of 5 is a family of one-dimensional symbols, 8 of which are supported by Zint. Note that the names given to these standards alters from one source to another so you should take care to ensure that you have the right barcode type before using these standards.

6.1.2.1 Standard Code 2 of 5

zint -b C25STANDARD -d "9212320967"

Also known as Code 2 of 5 Matrix, this is a self-checking code used in industrial applications and photo development. Standard Code 2 of 5 will encode numeric input (digits 0-9) up to a maximum of 112 digits. No check digit is added by default. To add a check digit, set --vers=1 (API option_2 = 1). To add a check digit but not show it in the Human Readable Text, set --vers=2 (API option_2 = 2).

6.1.2.2 IATA Code 2 of 5

zint -b C25IATA -d "9212320967"

Used for baggage handling in the air-transport industry by the International Air Transport Agency, this self-checking code will encode numeric input (digits 0-9) up to a maximum of 80 digits. No check digit is added by default, but can be set the same as for 6.1.2.1 Standard Code 2 of 5.

6.1.2.3 Industrial Code 2 of 5

zint -b C25IND -d "9212320967"

Industrial Code 2 of 5 can encode numeric input (digits 0-9) up to a maximum of 79 digits. No check digit is added by default, but can be set the same as for 6.1.2.1 Standard Code 2 of 5.

6.1.2.4 Interleaved Code 2 of 5 (ISO 16390)

zint -b C25INTER --compliantheight -d "9212320967"

This self-checking symbology encodes pairs of numbers, and so can only encode an even number of digits (0-9). If an odd number of digits is entered a leading zero is added by Zint. A maximum of 62 pairs (124 digits) can be encoded. No check digit is added by default, but can be set the same as for 6.1.2.1 Standard Code 2 of 5.

6.1.2.5 Code 2 of 5 Data Logic

zint -b C25LOGIC -d "9212320967"

Data Logic does not include a check digit by default and can encode numeric input (digits 0-9) up to a maximum of 113 digits. Check digit options are the same as for 6.1.2.1 Standard Code 2 of 5.

6.1.2.6 ITF-14

zint -b ITF14 --compliantheight -d "9212320967145"

ITF-14, also known as UPC Shipping Container Symbol or Case Code, is based on Interleaved Code 2 of 5 and requires a 13-digit numeric input (digits 0-9). One modulo-10 check digit is added by Zint.

If no border option is specified Zint defaults to adding a bounding box with a border width of 5. This behaviour can be overridden by using the --bind option (API output_options |= BARCODE_BIND). Similarly the border width can be overridden using --border (API border_width). If a symbol with no border is required this can be achieved by explicitly setting the border type to box (or bind or bindtop) and leaving the border width 0.

zint -b ITF14 --box --compliantheight -d "9212320967145"

6.1.2.7 Deutsche Post Leitcode

zint -b DPLEIT -d "9212320967145"

Leitcode is based on Interleaved Code 2 of 5 and is used by Deutsche Post for routing purposes. Leitcode requires a 13-digit numerical input to which Zint adds a check digit.

6.1.2.8 Deutsche Post Identcode

zint -b DPIDENT -d "91232096712"

Identcode is based on Interleaved Code 2 of 5 and is used by Deutsche Post for identification purposes. Identcode requires an 11-digit numerical input to which Zint adds a check digit.

6.1.3 UPC (Universal Product Code) (ISO 15420)

6.1.3.1 UPC Version A

zint -b UPCA --compliantheight -d "72527270270"

UPC-A is used in the United States for retail applications. The symbol requires an 11-digit article number. The check digit is calculated by Zint. In addition EAN-2 and EAN-5 add-on symbols can be added using the + character. For example, to draw a UPC-A symbol with the data 72527270270 with an EAN-5 add-on showing the data 12345 use the command:

zint -b UPCA -d "72527270270+12345"

or using the API encode a data string with the + character included:

my_symbol->symbology = BARCODE_UPCA;
error = ZBarcode_Encode_and_Print(my_symbol, "72527270270+12345", 0, 0);
zint -b UPCA --compliantheight -d "72527270270+12345"

If your input data already includes the check digit symbology BARCODE_UPCA_CHK (35) can be used which takes a 12-digit input and validates the check digit before encoding.

A quiet zone indicator can be added to the HRT by setting --guardwhitespace (API output_options |= EANUPC_GUARD_WHITESPACE). For UPC, this is only relevant when there is add-on:

zint -b UPCA -d "72527270270+12345" --guardwhitespace

or using the API:

my_symbol->symbology = BARCODE_UPCA;
my_symbol->output_options |= EANUPC_GUARD_WHITESPACE;
error = ZBarcode_Encode_and_Print(my_symbol, "72527270270+12345", 0, 0);
zint -b UPCA --compliantheight -d "72527270270+12345" --guardwhitespace

You can adjust the gap between the main symbol and an add-on in integral multiples of the X-dimension by setting --addongap (API option_2) to a value between 9 (default) and 12. The height in X-dimensions that the guard bars descend below the main bars can be adjusted by setting --guarddescent (API guard_descent) to a value between 0.0 and 20.0 (default 5.0).

6.1.3.2 UPC Version E

zint -b UPCE --compliantheight -d "1123456"

UPC-E is a zero-compressed version of UPC-A developed for smaller packages. The code requires a 6-digit article number (digits 0-9). The check digit is calculated by Zint. EAN-2 and EAN-5 add-on symbols can be added using the + character as with UPC-A. In addition Zint also supports Number System 1 encoding by entering a 7-digit article number starting with the digit 1. For example:

zint -b UPCE -d "1123456"

or

my_symbol->symbology = BARCODE_UPCE;
error = ZBarcode_Encode_and_Print(my_symbol, "1123456", 0, 0);

If your input data already includes the check digit symbology BARCODE_UPCE_CHK (38) can be used which takes a 7 or 8-digit input and validates the check digit before encoding.

As with UPC-A, a quiet zone indicator can be added when there is an add-on by setting --guardwhitespace (API output_options |= EANUPC_GUARD_WHITESPACE):

zint -b UPCE -d "1123456+12" --guardwhitespace
zint -b UPCE --compliantheight -d "1123456+12" --guardwhitespace

You can adjust the gap between the main symbol and an add-on in integral multiples of the X-dimension by setting --addongap (API option_2) to a value between 7 (default) and 12. The height in X-dimensions that the guard bars descend below the main bars can be adjusted by setting --guarddescent (API guard_descent) to a value between 0.0 and 20.0 (default 5.0).

6.1.4 EAN (European Article Number) (ISO 15420)

6.1.4.1 EAN-2, EAN-5, EAN-8 and EAN-13

zint -b EANX --compliantheight -d "4512345678906"

The EAN system is used in retail across Europe and includes standards for EAN-2, EAN-5, EAN-8 and EAN-13 which encode 2, 5, 7 or 12-digit numbers respectively. Zint will decide which symbology to use depending on the length of the input data. In addition EAN-2 and EAN-5 add-on symbols can be added to EAN-8 and EAN-13 symbols using the + character as with UPC symbols. For example:

zint -b EANX -d "54321"
zint -b EANX --compliantheight -d "54321"

will encode a stand-alone EAN-5, whereas

zint -b EANX -d "7432365+54321"

will encode an EAN-8 symbol with an EAN-5 add-on. As before these results can be achieved using the API:

my_symbol->symbology = BARCODE_EANX;

error = ZBarcode_Encode_and_Print(my_symbol, "54321", 0, 0);

error = ZBarcode_Encode_and_Print(my_symbol, "7432365+54321", 0, 0);
zint -b EANX --compliantheight -d "7432365+54321"

All of the EAN symbols include check digits which are added by Zint.

If you are encoding an EAN-8 or EAN-13 symbol and your data already includes the check digit then you can use symbology BARCODE_EANX_CHK (14) which takes an 8 or 13-digit input and validates the check digit before encoding.

Options to add quiet zone indicators and to adjust the add-on gap and the guard bar descent height are the same as for 6.1.3.2 UPC Version E. For instance:

zint -b EANX_CHK -d "74323654" --guardwhitespace
zint -b EANX_CHK --compliantheight -d "74323654" –guardwhitespace

6.1.4.2 SBN, ISBN and ISBN-13

zint -b ISBNX --compliantheight -d "9789295055124"

EAN-13 symbols (also known as Bookland EAN-13) can also be produced from 9-digit SBN, 10-digit ISBN or 13-digit ISBN-13 data. The relevant check digit needs to be present in the input data and will be verified before the symbol is generated.

As with EAN-13, a quiet zone indicator can be added using --guardwhitespace:

zint -b ISBNX --compliantheight -d "9789295055124" --guardwhitespace

EAN-2 and EAN-5 add-on symbols can be added using the + character, and there are options to adjust the add-on gap and the guard bar descent height - see 6.1.3.2 UPC Version E.

6.1.5 Plessey

6.1.5.1 UK Plessey

zint -b PLESSEY -d "C64"

Also known as Plessey Code, this symbology was developed by the Plessey Company Ltd. in the UK. The symbol can encode data consisting of digits (0-9) or letters A-F up to a maximum of 67 characters and includes a hidden CRC check digit.

6.1.5.2 MSI Plessey

zint -b MSI_PLESSEY -d "6502" --vers=2

Based on Plessey and developed by MSI Data Corporation, MSI Plessey can encode numeric (digits 0-9) input of up to 92 digits. It has a range of check digit options that are selectable by setting --vers (API option_2), shown in the table below:

Table : MSI Plessey Check Digit Options
Value Check Digits
0 None
1 Modulo-10 (Luhn)
2 Modulo-10 & Modulo-10
3 Modulo-11 (IBM)
4 Modulo-11 (IBM) & Modulo-10
5 Modulo-11 (NCR)
6 Modulo-11 (NCR) & Modulo-10

To not show the check digit or digits in the Human Readable Text, add 10 to the --vers value. For example --vers=12 (API option_2 = 12) will add two hidden modulo-10 check digits.

6.1.6 Telepen

6.1.6.1 Telepen Alpha

zint -b TELEPEN --compliantheight -d "Z80"

Telepen Alpha was developed by SB Electronic Systems Limited and can encode ASCII text input, up to a maximum of 69 characters. Telepen includes a hidden modulo-127 check digit, added by Zint.

6.1.6.2 Telepen Numeric

zint -b TELEPEN_NUM --compliantheight -d "466X33"

Telepen Numeric allows compression of numeric data into a Telepen symbol. Data can consist of pairs of numbers or pairs consisting of a numerical digit followed an X character. For example: 466333 and 466X33 are valid codes whereas 46X333 is not (the digit pair "X3" is not valid). Up to 136 digits can be encoded. Telepen Numeric includes a hidden modulo-127 check digit which is added by Zint.

6.1.7 Code 39

6.1.7.1 Standard Code 39 (ISO 16388)

zint -b CODE39 --compliantheight -d "1A" --vers=1

Standard Code 39 was developed in 1974 by Intermec. Input data can be up to 86 characters in length and can include the characters 0-9, A-Z, dash (-), full stop (.), space, asterisk (*), dollar ($), slash (/), plus (+) and percent (%). The standard does not require a check digit but a modulo-43 check digit can be added if desired by setting --vers=1 (API option_2 = 1). To add a check digit but not show it in the Human Readable Text, set --vers=2 (API option_2 = 2).

6.1.7.2 Extended Code 39

zint -b EXCODE39 --compliantheight -d "123.45$@fd"

Also known as Code 39e and Code39+, this symbology expands on Standard Code 39 to provide support for the full 7-bit ASCII character set. The check digit options are the same as for 6.1.7.1 Standard Code 39 (ISO 16388).

6.1.7.3 Code 93

zint -b CODE93 --compliantheight -d "C93"

A variation of Extended Code 39, Code 93 also supports full ASCII text, accepting up to 123 characters. Two check characters are added by Zint. By default these check characters are not shown in the Human Readable Text, but may be shown by setting --vers=1 (API option_2 = 1).

6.1.7.4 PZN (Pharmazentralnummer)

zint -b PZN --compliantheight -d "2758089"

PZN is a Code 39 based symbology used by the pharmaceutical industry in Germany. PZN encodes a 7-digit number to which Zint will add a modulo-11 check digit (PZN8). Input less than 7 digits will be zero-filled. An 8-digit input can be supplied in which case Zint will validate the check digit.

To encode a PZN7 (obsolete since 2013) instead set --vers=1 (API option_2 = 1) and supply up to 7 digits. As with PZN8, a modulo-11 check digit will be added or if 7 digits supplied the check digit validated.

6.1.7.5 LOGMARS

zint -b LOGMARS --compliantheight -d "12345/ABCDE" --vers=1

LOGMARS (Logistics Applications of Automated Marking and Reading Symbols) is a variation of the Code 39 symbology used by the U.S. Department of Defense. LOGMARS encodes the same character set as 6.1.7.1 Standard Code 39 (ISO 16388), and the check digit options are also the same. Input is restricted to a maximum of 30 characters.

6.1.7.6 Code 32

zint -b CODE32 --compliantheight -d "14352312"

A variation of Code 39 used by the Italian Ministry of Health (“Ministero della Sanità”) for encoding identifiers on pharmaceutical products. This symbology requires a numeric input up to 8 digits in length. A check digit is added by Zint.

6.1.7.7 HIBC Code 39

zint -b HIBC_39 --compliantheight -d "14352312"

This variant adds a leading '+' character and a trailing modulo-49 check digit to a standard Code 39 symbol as required by the Health Industry Barcode standards.

6.1.7.8 Vehicle Identification Number (VIN)

zint -b VIN -d "2FTPX28L0XCA15511" --vers=1

A variation of Code 39 that for vehicle identification numbers used in North America (first character '1' to '5') has a check character verification stage. A 17 character input (0-9, and A-Z excluding 'I', 'O' and 'Q') is required. An invisible Import character prefix 'I' can be added by setting --vers=1 (API option_2 = 1).

6.1.8 Codabar (EN 798)

zint -b CODABAR --compliantheight -d "A37859B"

Also known as NW-7, Monarch, ABC Codabar, USD-4, Ames Code and Code 27, this symbology was developed in 1972 by Monarch Marketing Systems for retail purposes. The American Blood Commission adopted Codabar in 1977 as the standard symbology for blood identification. Codabar can encode up to 103 characters starting and ending with the letters A-D and containing between these letters the numbers 0-9, dash (-), dollar ($), colon (:), slash (/), full stop (.) or plus (+). No check character is generated by default, but a modulo-16 one can be added by setting --vers=1 (API option_2 = 1). To have the check character appear in the Human Readable Text, set --vers=2 (API option_2 = 2).

6.1.9 Pharmacode

zint -b PHARMA --compliantheight -d "130170"

Developed by Laetus, Pharmacode is used for the identification of pharmaceuticals. The symbology is able to encode whole numbers between 3 and 131070.

6.1.10 Code 128

6.1.10.1 Standard Code 128 (ISO 15417)

zint -b CODE128 --bind -d "130170X178"

One of the most ubiquitous one-dimensional barcode symbologies, Code 128 was developed in 1981 by Computer Identics. This symbology supports full ASCII text and uses a three-Code Set system to compress the data into a smaller symbol. Zint automatically switches between Code Sets A, B and C (but see following) and adds a hidden modulo-103 check digit.

Manual switching of Code Sets is possible using the --extraesc option (API input_mode |= EXTRA_ESCAPE_MODE) and the Code 128-specific escapes \^A, \^B, \^C. For instance the following will force switching to Code Set B for the data "5678" (normally Code Set C would be used throughout):

zint -b CODE128 -d "1234\^B5678" --extraesc

The manually selected Code Set will apply until the next Code Set escape sequence, with the exception that data that cannot be represented in that Code Set will be switched as appropriate. If the data contains a special code sequence, it can be escaped by doubling the caret (^). For instance

zint -b CODE128 -d "\^AABC\^^BDEF" --extraesc

will encode the data "ABC\^BDEF" in Code Set A.

There is also the extra escape \^1, which will encode a special Function Code 1 character (FNC1) anywhere you chose in the data, for instance

zint -b CODE128 -d "A\^1BC\^1DEF" --extraesc

Code 128 is the default barcode symbology used by Zint. In addition Zint supports the encoding of ISO/IEC 8859-1 (non-English) characters in Code 128 symbols. The ISO/IEC 8859-1 character set is shown in Annex A.2 Latin Alphabet No. 1 (ISO/IEC 8859-1).

Zint can encode a maximum of 99 symbol characters, which allows for e.g. 198 all-numeric characters.

6.1.10.2 Code 128 Suppress Code Set C (Code Sets A and B only)

zint -b CODE128AB -d "130170X178"

It is sometimes advantageous to stop Code 128 from using Code Set C which compresses numerical data. The BARCODE_CODE128AB14 variant (symbology 60) suppresses Code Set C in favour of Code Sets A and B.

Note that the special extra escapes mentioned above are not available for this variant (nor for any other).

6.1.10.3 GS1-128

zint -b GS1_128 --compliantheight -d "[01]98898765432106[3202]012345[15]991231"

A variation of Code 128 previously known as UCC/EAN-128, this symbology is defined by the GS1 General Specifications. Application Identifiers (AIs) should be entered using [square bracket] notation. These will be converted to parentheses (round brackets) for the Human Readable Text. This will allow round brackets to be used in the data strings to be encoded.

For compatibility with data entry in other systems, if the data does not include round brackets, the option --gs1parens (API input_mode |= GS1PARENS_MODE) may be used to signal that AIs are encased in round brackets instead of square ones.

Fixed length data should be entered at the appropriate length for correct encoding. GS1-128 does not support extended ASCII (ISO/IEC 8859-1) characters. Check digits for GTIN data AI (01) are not generated and need to be included in the input data. The following is an example of a valid GS1-128 input:

zint -b 16 -d "[01]98898765432106[3202]012345[15]991231"

or using the --gs1parens option:

zint -b 16 --gs1parens -d "(01)98898765432106(3202)012345(15)991231"

6.1.10.4 EAN-14

zint -b EAN14 --compliantheight -d "9889876543210"

A shorter version of GS1-128 which encodes GTIN data only. A 13-digit number is required. The GTIN check digit and HRT-only AI “(01)” are added by Zint.

6.1.10.5 NVE-18 (SSCC-18)

zint -b NVE18 --compliantheight -d "37612345000001003"

A variation of Code 128 the ‘Nummer der Versandeinheit’ standard, also known as SSCC-18 (Serial Shipping Container Code), includes both a visible modulo-10 and a hidden modulo-103 check digit. NVE-18 requires a 17-digit numerical input. Check digits and HRT-only AI “(00)” are added by Zint.

6.1.10.6 HIBC Code 128

zint -b HIBC_128 -d "A123BJC5D6E71"

This option adds a leading '+' character and a trailing modulo-49 check digit to a standard Code 128 symbol as required by the Health Industry Barcode standards.

6.1.10.7 DPD Code

zint -b DPD --compliantheight -d "000393206219912345678101040"

Another variation of Code 128 as used by DPD (Deutscher Paketdienst). Requires a 27 or 28 character input. For 28 character input, the first character is an identification tag (Barcode ID), which should usually be "%" (ASCII 37). If 27 characters are supplied, "%" will be prefixed by Zint (except if marked as a “relabel”, see below). The rest of the 27-character input must be alphanumeric, and is of the form:

Table : DPD Input Fields
Destination Post Code Tracking Number Service Code Destination Country Code
PPPPPPP (7 alphanumerics) TTTTTTTTTTTTTT (14 alphanumerics) SSS (3 digits) CCC (3-digit ISO 3166-1)

A warning will be generated if the Service Code, the Destination Country Code, or the last 10 characters of the Tracking Number are non-numeric.

Zint formats the Human Readable Text as specified by DPD, leaving out the identication tag, and adds a modulo-36 check character to the text (not to the barcode itself), thus:

PPPP PPP TTTT TTTT TTTT TT SSS CCC D

By default a top boundary bar is added, with default width 3X. The width can be overridden using --border (API border_width). For a symbol with no top boundary bar, explicitly set the border type to bindtop (or bind or box) and leave the border width 0.

A DPD Code can be marked as a “relabel” by specifying --vers=1 (API option_2 = 1), which omits the identification tag and prints the barcode at half height. In this case, an input of 27 alphanumeric characters is required.

6.1.10.8 UPU S10

zint -b UPU_S10 --compliantheight -d "EE876543216CA"

The Universal Postal Union S10 variant of Code 128 encodes 13 characters in the format "SSNNNNNNNNXCC", where "SS" is a two-character alphabetic service indicator, "NNNNNNNN" is an 8-digit serial number, "X" is a modulo-11 check digit, and "CC" is a two-character ISO 3166-1 country code.

The check digit may be omitted in which case Zint will add it. Warnings will be generated if the service indicator is non-standard or the country code is not ISO 3361-1.

6.1.11 GS1 DataBar (ISO 24724)

Previously known as RSS (Reduced Spaced Symbology), these symbols are due to replace GS1-128 symbols in accordance with the GS1 General Specifications. If a GS1 DataBar symbol is to be printed with a 2D component as specified in ISO/IEC 24723 set --mode=2 (API option_1 = 2). See 6.3 GS1 Composite Symbols (ISO 24723) to find out how to generate DataBar symbols with 2D components.

6.1.11.1 GS1 DataBar Omnidirectional and GS1 DataBar Truncated

zint -b DBAR_OMN --compliantheight -d "0950110153001"

Previously known as RSS-14 this standard encodes a 13-digit item code. A check digit and HRT-only Application Identifier of “(01)” are added by Zint. (A 14-digit code that appends the check digit may be given, in which case the check digit will be verified.)

GS1 DataBar Omnidirectional symbols should have a height of 33 or greater. To produce a GS1 DataBar Truncated symbol set the symbol height to a value between 13 and 32. Truncated symbols may not be scannable by omnidirectional scanners.

zint -b DBAR_OMN -d "0950110153001" --height=13

6.1.11.2 GS1 DataBar Limited

zint -b DBAR_LTD --compliantheight -d "0950110153001"

Previously known as RSS Limited this standard encodes a 13-digit item code and can be used in the same way as GS1 DataBar Omnidirectional above. GS1 DataBar Limited, however, is limited to data starting with digits 0 and 1 (i.e. numbers in the range 0 to 1999999999999). As with GS1 DataBar Omnidirectional a check digit and HRT-only Application Identifier of “(01)” are added by Zint, and a 14-digit code may be given in which case the check digit will be verified.

6.1.11.3 GS1 DataBar Expanded

zint -b DBAR_EXP --compliantheight -d "[01]98898765432106[3202]012345[15]991231"

Previously known as RSS Expanded this is a variable length symbology capable of encoding data from a number of AIs in a single symbol. AIs should be encased in [square brackets] in the input data, which will be converted to parentheses (round brackets) before being included in the Human Readable Text attached to the symbol. This method allows the inclusion of parentheses in the data to be encoded. If the data does not include parentheses, the AIs may alternatively be encased in parentheses using the --gs1parens switch. See 6.1.10.3 GS1-128.

GTIN data AI (01) should also include the check digit data as this is not calculated by Zint when this symbology is encoded. Fixed length data should be entered at the appropriate length for correct encoding. The following is an example of a valid GS1 DataBar Expanded input:

zint -b 31 -d "[01]98898765432106[3202]012345[15]991231"

6.1.12 Korea Post Barcode

zint -b KOREAPOST -d "923457"

The Korean Postal Barcode is used to encode a 6-digit number and includes one check digit.

6.1.13 Channel Code

zint -b CHANNEL -d "453678" --compliantheight

A highly compressed symbol for numeric data. The number of channels in the symbol can be between 3 and 8 and this can be specified by setting the value of the --vers option (API option_2). It can also be determined by the length of the input data: e.g. a three character input string generates a 4 channel code by default.

The maximum values permitted depend on the number of channels used as shown in the table below:

Table : Channel Value Ranges
Channels Minimum Value Maximum Value
3 00 26
4 000 292
5 0000 3493
6 00000 44072
7 000000 576688
8 0000000 7742862

6.1.14 BC412 (SEMI T1-95)

zint -b BC412 -d "AQ45670" --compliantheight

Designed by IBM for marking silicon wafers, each BC412 character is represented by 4 bars of a single size, interleaved with 4 spaces of varying sizes that total 8 (hence 4 bars in 12). Zint implements the SEMI T1-95 standard, where input must be alphanumeric, excluding the letter O, and must be from 7 to 18 characters in length. A single check character is added by Zint, appearing in the 2nd character position. Lowercase input is automatically made uppercase.

6.2 Stacked Symbologies

6.2.1 Basic Symbol Stacking

An early innovation to get more information into a symbol, used primarily in the vehicle industry, is to simply stack one-dimensional codes on top of each other. This can be achieved at the command prompt by giving more than one set of input data. For example

zint -d "This" -d "That"

will draw two Code 128 symbols, one on top of the other. The same result can be achieved using the API by executing the ZBarcode_Encode() function more than once on a symbol. For example:

my_symbol->symbology = BARCODE_CODE128;

error = ZBarcode_Encode(my_symbol, "This", 0);

error = ZBarcode_Encode(my_symbol, "That", 0);

error = ZBarcode_Print(my_symbol);
zint -d "This" -d "That"

Note that the Human Readable Text will be that of the last data, so it’s best to use the option --notext (API show_hrt = 0).

The stacked barcode rows can be separated by row separator bars by specifying --bind (API output_options |= BARCODE_BIND). The height of the row separator bars in integral multiples of the X-dimension (minimum and default 1, maximum 4) can be set by --separator (API option_3):

zint --bind --notext --separator=2 -d "This" -d "That"
zint --notext --bind --separator=2 -d "This" -d "That"

A more sophisticated method is to use some type of line indexing which indicates to the barcode reader which order the stacked symbols should be read in. This is demonstrated by the symbologies below.

6.2.2 Codablock-F

zint -b CODABLOCKF -d "CODABLOCK F Symbology" --rows=3

This is a stacked symbology based on Code 128 which can encode Latin-1 data up to a maximum length of 2725 characters. The width of the Codablock-F symbol can be set using the --cols option (API option_2), to a value between 9 and 67. The height (number of rows) can be set using the --rows option (API option_1), with a maximum of 44. Zint does not currently support encoding of GS1 data in Codablock-F symbols.

A separate symbology ID (BARCODE_HIBC_BLOCKF) can be used to encode Health Industry Barcode (HIBC) data which adds a leading '+' character and a modulo-49 check digit to the encoded data.

6.2.3 Code 16K (EN 12323)

zint -b CODE16K --compliantheight -d "ab0123456789"

Code 16K uses a Code 128 based system which can stack up to 16 rows in a block. This gives a maximum data capacity of 77 characters or 154 numerical digits and includes two modulo-107 check digits. Code 16K also supports ISO/IEC 8859-1 character encoding in the same manner as Code 128. GS1 data encoding is also supported. The minimum number of rows to use can be set using the --rows option (API option_1), with values from 2 to 16.

6.2.4 PDF417 (ISO 15438)

zint -b PDF417 -d "PDF417"

Heavily used in the parcel industry, the PDF417 symbology can encode a vast amount of data into a small space. Zint supports encoding up to the ISO standard maximum symbol size of 925 codewords which (at error correction level 0) allows a maximum data size of 1850 text characters, or 2710 digits.

The width of the generated PDF417 symbol can be specified at the command line using the --cols switch (API option_2) followed by a number between 1 and 30, the number of rows using the --rows switch (API option_3) followed by a number between 3 and 90, and the amount of error correction information can be specified by using the --secure switch (API option_1) followed by a number between 0 and 8 where the number of codewords used for error correction is determined by 2^(value + 1). The default level of error correction is determined by the amount of data being encoded.

This symbology uses Latin-1 character encoding by default but also supports the ECI encoding mechanism. A separate symbology ID (BARCODE_HIBC_PDF) can be used to encode Health Industry Barcode (HIBC) data.

For a faster but less optimal encoding, the --fast option (API input_mode |= FAST_MODE) may be used.

PDF417 supports Structured Append of up to 99,999 symbols and an optional numeric ID of up to 30 digits, which can be set by using the --structapp option (see 4.17 Structured Append) (API structapp). The ID consists of up to 10 triplets, each ranging from "000" to "899". For instance "123456789" would be a valid ID of 3 triplets. However "123456900" would not, as the last triplet "900" exceeds "899". The triplets are 0-filled, for instance "1234" becomes "123004". If an ID is not given, no ID is encoded.

6.2.5 Compact PDF417 (ISO 15438)

zint -b PDF417COMP -d "PDF417"

Previously known as Truncated PDF417, Compact PDF417 omits some per-row overhead to produce a narrower but less robust symbol. Options are the same as for PDF417 above.

6.2.6 MicroPDF417 (ISO 24728)

zint -b MICROPDF417 -d "12345678"

A variation of the PDF417 standard, MicroPDF417 is intended for applications where symbol size needs to be kept to a minimum. 34 predefined symbol sizes are available with 1 - 4 columns and 4 - 44 rows. The maximum amount a MicroPDF417 symbol can hold is 250 alphanumeric characters or 366 digits. The amount of error correction used is dependent on symbol size. The number of columns used can be determined using the --cols switch (API option_2) as with PDF417.

This symbology uses Latin-1 character encoding by default but also supports the ECI encoding mechanism. A separate symbology ID (BARCODE_HIBC_MICPDF) can be used to encode Health Industry Barcode (HIBC) data. MicroPDF417 supports FAST_MODE and Structured Append the same as PDF417, for which see details.

6.2.7 GS1 DataBar Stacked (ISO 24724)

6.2.7.1 GS1 DataBar Stacked

zint -b DBAR_STK --compliantheight -d "9889876543210"

A stacked variation of the GS1 DataBar Truncated symbol requiring the same input (see 6.1.11.1 GS1 DataBar Omnidirectional and GS1 DataBar Truncated), this symbol is the same as the following GS1 DataBar Stacked Omnidirectional symbol except that its height is reduced and its central separator is a single row, making it suitable for small items when omnidirectional scanning is not required. It can be generated with a two-dimensional component to make a composite symbol.

6.2.7.2 GS1 DataBar Stacked Omnidirectional

zint -b DBAR_OMNSTK --compliantheight -d "9889876543210"

A stacked variation of the GS1 DataBar Omnidirectional symbol requiring the same input (see 6.1.11.1 GS1 DataBar Omnidirectional and GS1 DataBar Truncated). The data is encoded in two rows of bars with a central 3-row separator. This symbol can be generated with a two-dimensional component to make a composite symbol.

6.2.7.3 GS1 DataBar Expanded Stacked

zint -b DBAR_EXPSTK --compliantheight -d "[01]98898765432106[3202]012345[15]991231"

A stacked variation of the GS1 DataBar Expanded symbol for smaller packages. Input is the same as for GS1 DataBar Expanded (see 6.1.11.3 GS1 DataBar Expanded). In addition the width of the symbol can be altered using the --cols switch (API option_2). In this case the number of columns (values 1 to 11) relates to the number of character pairs on each row of the symbol. Alternatively the --rows switch (API option_3) can be used to specify the maximum number of rows (values 2 to 11), and the number of columns will be adjusted accordingly. This symbol can be generated with a two-dimensional component to make a composite symbol. For symbols with a 2D component the number of columns must be at least 2.

6.2.8 Code 49

zint -b CODE49 --compliantheight -d "MULTIPLE ROWS IN CODE 49"

Developed in 1987 at Intermec, Code 49 is a cross between UPC and Code 39. It is one of the earliest stacked symbologies and influenced the design of Code 16K a few years later. It supports full 7-bit ASCII input up to a maximum of 49 characters or 81 numeric digits. GS1 data encoding is also supported. The minimum number of rows to use can be set using the --rows option (API option_1), with values from 2 to 8.

6.3 GS1 Composite Symbols (ISO 24723)

GS1 Composite symbols employ a mixture of components to give more comprehensive information about a product. The permissible contents of a composite symbol is determined by the terms of the GS1 General Specifications. Composite symbols consist of a linear component which can be an EAN, UPC, GS1-128 or GS1 DataBar symbol, a two-dimensional (2D) component which is based on PDF417 or MicroPDF417, and a separator pattern. The type of linear component to be used is determined using the -b or --barcode switch (API symbology) as with other encoding methods. Valid values are shown below.

Table : GS1 Composite Symbology Values
Numeric Value Name Barcode Name
130 BARCODE_EANX_CC GS1 Composite Symbol with EAN linear component
131 BARCODE_GS1_128_CC GS1 Composite Symbol with GS1-128 linear component
132 BARCODE_DBAR_OMN_CC GS1 Composite Symbol with GS1 DataBar Omnidirectional linear component
133 BARCODE_DBAR_LTD_CC GS1 Composite Symbol with GS1 DataBar Limited linear component
134 BARCODE_DBAR_EXP_CC GS1 Composite Symbol with GS1 DataBar Expanded linear component
135 BARCODE_UPCA_CC GS1 Composite Symbol with UPC-A linear component
136 BARCODE_UPCE_CC GS1 Composite Symbol with UPC-E linear component
137 BARCODE_DBAR_STK_CC GS1 Composite Symbol with GS1 DataBar Stacked component
138 BARCODE_DBAR_OMNSTK_CC GS1 Composite Symbol with GS1 DataBar Stacked Omnidirectional component
139 BARCODE_DBAR_EXPSTK_CC GS1 Composite Symbol with GS1 DataBar Expanded Stacked component

The data to be encoded in the linear component of a composite symbol should be entered into a primary string with the data for the 2D component being entered in the normal way. To do this at the command prompt use the --primary switch (API primary). For example:

zint -b EANX_CC --mode=1 --primary=331234567890 -d "[99]1234-abcd"

This creates an EAN-13 linear component with the data "331234567890" and a 2D CC-A (see below) component with the data "(99)1234-abcd". The same results can be achieved using the API as shown below:

my_symbol->symbology = BARCODE_EANX_CC;

my_symbol->option_1 = 1;

strcpy(my_symbol->primary, "331234567890");

ZBarcode_Encode_and_Print(my_symbol, "[99]1234-abcd", 0, 0);

EAN-2 and EAN-5 add-on data can be used with EAN and UPC symbols using the + symbol as described in sections 6.1.3 UPC (Universal Product Code) (ISO 15420) and 6.1.4 EAN (European Article Number) (ISO 15420).

The 2D component of a composite symbol can use one of three systems: CC-A, CC-B and CC-C, as described below. The 2D component type can be selected automatically by Zint dependent on the length of the input string. Alternatively the three methods can be accessed using the --mode prompt (API option_1) followed by 1, 2 or 3 for CC-A, CC-B or CC-C respectively.

6.3.1 CC-A

zint -b EANX_CC --compliantheight -d "[99]1234-abcd" --mode=1 --primary=331234567890

This system uses a variation of MicroPDF417 which is optimised to fit into a small space. The size of the 2D component and the amount of error correction is determined by the amount of data to be encoded and the type of linear component which is being used. CC-A can encode up to 56 numeric digits or an alphanumeric string of shorter length. To select CC-A use --mode=1 (API option_1 = 1).

6.3.2 CC-B

zint -b EANX_CC --compliantheight -d "[99]1234-abcd" --mode=2 --primary=331234567890

This system uses MicroPDF417 to encode the 2D component. The size of the 2D component and the amount of error correction is determined by the amount of data to be encoded and the type of linear component which is being used. CC-B can encode up to 338 numeric digits or an alphanumeric string of shorter length. To select CC-B use --mode=2 (API option_1 = 2).

6.3.3 CC-C

zint -b GS1_128_CC --compliantheight -d "[99]1234-abcd" --mode=3 --primary="[01]03312345678903"

This system uses PDF417 and can only be used in conjunction with a GS1-128 linear component. CC-C can encode up to 2361 numeric digits or an alphanumeric string of shorter length. To select CC-C use --mode=3 (API option_1 = 3).

6.4 Two-Track Symbols

6.4.1 Two-Track Pharmacode

zint -b PHARMA_TWO --compliantheight -d "29876543"

Developed by Laetus, Pharmacode Two-Track is an alternative system to Pharmacode One-Track (see 6.1.9 Pharmacode) used for the identification of pharmaceuticals. The symbology is able to encode whole numbers between 4 and 64570080.

6.4.2 POSTNET

zint -b POSTNET --compliantheight -d "12345678901"

Used by the United States Postal Service until 2009, the POSTNET barcode was used for encoding zip-codes on mail items. POSTNET uses numerical input data and includes a modulo-10 check digit. While Zint will encode POSTNET symbols of up to 38 digits in length, standard lengths as used by USPS were PostNet6 (5-digit ZIP input), PostNet10 (5-digit ZIP + 4-digit user data) and PostNet12 (5-digit ZIP + 6-digit user data), and a warning will be issued if the input length is not one of these.

6.4.3 PLANET

zint -b PLANET --compliantheight -d "4012345235636"

Used by the United States Postal Service until 2009, the PLANET (Postal Alpha Numeric Encoding Technique) barcode was used for encoding routing data on mail items. PLANET uses numerical input data and includes a modulo-10 check digit. While Zint will encode PLANET symbols of up to 38 digits in length, standard lengths used by USPS were Planet12 (11-digit input) and Planet14 (13-digit input), and as with POSTNET a warning will be issued if the length is not one of these.

6.4.4 Brazilian CEPNet

zint -b CEPNET --compliantheight -d "12345678"

Based on POSTNET, the CEPNet symbol is used by Correios, the Brazilian postal service, to encode CEP (Código de Endereçamento Postal) numbers on mail items. Input should consist of eight digits with the check digit being automatically added by Zint.

6.5 4-State Postal Codes

6.5.1 Australia Post 4-State Symbols

6.5.1.1 Customer Barcodes

zint -b AUSPOST --compliantheight -d "96184209"

Australia Post Standard Customer Barcode, Customer Barcode 2 and Customer Barcode 3 are 37-bar, 52-bar and 67-bar specifications respectively, developed by Australia Post for printing Delivery Point ID (DPID) and customer information on mail items. Valid data characters are 0-9, A-Z, a-z, space and hash (#). A Format Control Code (FCC) is added by Zint and should not be included in the input data. Reed-Solomon error correction data is generated by Zint. Encoding behaviour is determined by the length of the input data according to the formula shown in the following table.

Table : Australia Post Input Formats
Input Length Required Input Format Symbol Length FCC Encoding Table
8 99999999 37-bar 11 None
13 99999999AAAAA 52-bar 59 C
16 9999999999999999 52-bar 59 N
18 99999999AAAAAAAAAA 67-bar 62 C
23 99999999999999999999999 67-bar 62 N

6.5.1.2 Reply Paid Barcode

zint -b AUSREPLY --compliantheight -d "12345678"

A Reply Paid version of the Australia Post 4-State Barcode (FCC 45) which requires an 8-digit DPID input.

6.5.1.3 Routing Barcode

zint -b AUSROUTE --compliantheight -d "34567890"

A Routing version of the Australia Post 4-State Barcode (FCC 87) which requires an 8-digit DPID input.

6.5.1.4 Redirect Barcode

zint -b AUSREDIRECT --compliantheight -d "98765432"

A Redirection version of the Australia Post 4-State Barcode (FCC 92) which requires an 8-digit DPID input.

6.5.2 Dutch Post KIX Code

zint -b KIX --compliantheight -d "2500GG30250"

This symbology is used by Royal Dutch TPG Post (Netherlands) for Postal code and automatic mail sorting. Data input can consist of numbers 0-9 and letters A-Z and needs to be 11 characters in length. No check digit is included.

6.5.3 Royal Mail 4-State Customer Code (RM4SCC)

zint -b RM4SCC --compliantheight -d "W1J0TR01"

The RM4SCC standard is used by the Royal Mail in the UK to encode postcode and customer data on mail items. Data input can consist of numbers 0-9 and letters A-Z and usually includes delivery postcode followed by house number. For example "W1J0TR01" for 1 Piccadilly Circus in London. Check digit data is generated by Zint.

6.5.4 Royal Mail 4-State Mailmark

zint -b MAILMARK_4S --compliantheight -d "1100000000000XY11"

Developed in 2014 as a replacement for RM4SCC this 4-state symbol includes Reed- Solomon error correction. Input is a pre-formatted alphanumeric string of 22 (for Barcode C) or 26 (for Barcode L) characters, producing a symbol with 66 or 78 bars respectively. The rules for the input data are complex, as summarized in the following table.

Table : Royal Mail 4-State Mailmark Input Fields
Format Version ID Class Supply Chain ID Item ID Destination+DPS
1 digit (0-4) 1 digit (0-3) 1 alphanum. (0-9A-E) 2 digits (C) or 6 digits (L) 8 digits 9 alphanumerics (1 of 6 patterns)

The 6 Destination+DPS (Destination Post Code plus Delivery Point Suffix) patterns are:

Table : Royal Mail Mailmark Destination+DPS Patterns:
FNFNLLNLS FFNNLLNLS FFNNNLLNL
FFNFNLLNL FNNLLNLSS FNNNLLNLS

where 'F' stands for full alphabetic (A-Z), 'L' for limited alphabetic (A-Z less 'CIKMOV'), 'N' for numeric (0-9), and 'S' for space.

Four of the permitted patterns include a number of trailing space characters - these will be appended by Zint if not included in the input data.

For the two-dimensional Data Matrix-based version, see 6.6.2 Royal Mail 2D Mailmark (CMDM) (Data Matrix).

6.5.5 USPS Intelligent Mail

zint -b USPS_IMAIL --compliantheight -d "01234567094987654321-01234"

Also known as the OneCode barcode and used in the U.S. by the United States Postal Service (USPS), the Intelligent Mail system replaced the POSTNET and PLANET symbologies in 2009. Intelligent Mail is a fixed length (65-bar) symbol which combines routing and customer information in a single symbol. Input data consists of a 20-digit tracking code, followed by a dash (-), followed by a delivery point zip-code which can be 0, 5, 9 or 11 digits in length. For example all of the following inputs are valid data entries:

6.5.6 Japanese Postal Code

zint -b JAPANPOST --compliantheight -d "15400233-16-4-205"

Used for address data on mail items for Japan Post. Accepted values are 0-9, A-Z and dash (-). A modulo 19 check digit is added by Zint.

6.5.7 DAFT Code

zint -b DAFT -d "AAFDTTDAFADTFTTFFFDATFTADTTFFTDAFAFDTF" --height=8.494 --vers=256

This is a method for creating 4-state codes where the data encoding is provided by an external program. Input data should consist of the letters 'D', 'A', 'F' and 'T' where these refer to descender, ascender, full (ascender and descender) and tracker (neither ascender nor descender) respectively. All other characters are invalid. The ratio of the tracker size to full height can be given in thousandths (permille) using the --vers option (API option_2). The default value is 250 (25%).

For example the following

zint -b DAFT -d AAFDTTDAFADTFTTFFFDATFTADTTFFTDAFAFDTF --height=8.494 --vers=256

produces the same barcode (see 6.5.3 Royal Mail 4-State Customer Code (RM4SCC)) as

zint -b RM4SCC --compliantheight -d "W1J0TR01"

6.6 Matrix Symbols

6.6.1 Data Matrix (ISO 16022)

zint -b HIBC_DM -d "/ACMRN123456/V200912190833" --fast --square

Also known as Semacode this symbology was developed in 1989 by Acuity CiMatrix in partnership with the U.S. DoD and NASA. The symbol can encode a large amount of data in a small area. Data Matrix encodes characters in the Latin-1 set by default but also supports encoding in other character sets using the ECI mechanism. It can also encode GS1 data. The size of the generated symbol can be adjusted using the --vers option (API option_2) as shown in the table below. A separate symbology ID (BARCODE_HIBC_DM) can be used to encode Health Industry Barcode (HIBC) data. Note that only ECC200 encoding is supported, the older standards have now been removed from Zint.

Table : Data Matrix Sizes
Input Symbol Size Input Symbol Size Input Symbol Size
1 10 x 10 11 36 x 36 21 104 x 104
2 12 x 12 12 40 x 40 22 120 x 120
3 14 x 14 13 44 x 44 23 132 x 132
4 16 x 16 14 48 x 48 24 144 x 144
5 18 x 18 15 52 x 52 25 8 x 18
6 20 x 20 16 64 x 64 26 8 x 32
7 22 x 22 17 72 x 72 28 12 x 26
8 24 x 24 18 80 x 80 28 12 x 36
9 26 x 26 19 88 x 88 29 16 x 36
10 32 x 32 20 96 x 96 30 16 x 48

The largest version 24 (144 x 144) can encode 3116 digits, around 2335 alphanumeric characters, or 1555 bytes of data.

When using automatic symbol sizes you can force Zint to use square symbols (versions 1-24) at the command line by using the option --square (API option_3 = DM_SQUARE).

Data Matrix Rectangular Extension (ISO/IEC 21471) codes may be generated with the following values as before:

Table : DMRE Sizes
Input Symbol Size Input Symbol Size
31 8 x 48 40 20 x 36
32 8 x 64 41 20 x 44
33 8 x 80 42 20 x 64
34 8 x 96 43 22 x 48
35 8 x 120 44 24 x 48
36 8 x 144 45 24 x 64
37 12 x 64 46 26 x 40
38 12 x 88 47 26 x 48
39 16 x 64 48 26 x 64

DMRE symbol sizes may be activated in automatic size mode using the option --dmre (API option_3 = DM_DMRE).

GS1 data may be encoded using FNC1 (default) or GS (Group Separator, ASCII 29) as separator. Use the option --gssep to change to GS (API output_options |= GS1_GS_SEPARATOR).

By default Zint uses a “de facto” codeword placement for symbols of size 144 x 144 (version 24). To override this and use the now clarified ISO/IEC standard placement, use option --dmiso144 (API option_3 |= DM_ISO_144).

For a faster but less optimal encoding, the --fast option (API input_mode |= FAST_MODE) may be used.

Data Matrix supports Structured Append of up to 16 symbols and a numeric ID (file identifications), which can be set by using the --structapp option (see 4.17 Structured Append) (API structapp). The ID consists of 2 numbers ID1 and ID2, each of which can range from 1 to 254, and is specified as the single number ID1 * 1000 + ID2, so for instance ID1 "123" and ID2 "234" would be given as "123234". Note that both ID1 and ID2 must be non-zero, so e.g. "123000" or "000123" would be invalid IDs. If an ID is not given it defaults to "001001".

6.6.2 Royal Mail 2D Mailmark (CMDM) (Data Matrix)

zint -b MAILMARK_2D -d "JGB 01Z999999900000001EC1A1AA1A0SN35TQ" --vers=30

This variant of Data Matrix, also known as “Complex Mail Data Mark” (CMDM), was introduced by Royal Mail along with 6.5.4 Royal Mail 4-State Mailmark, and offers space for customer data following an initial pre-formatted 45 character section, as summarized below.

Table : Royal Mail 2D Mailmark Input Fields
Field Name Length Values
UPU Country ID 4 "JGB "
Information Type 1 Alphanumeric
Version ID 1 "1"
Class 1 Alphanumeric
Supply Chain ID 7 Numeric
Item ID 8 Numeric
Destination+DPS 9 Alphanumeric (1 of 6 patterns)
Service Type 1 Numeric
RTS Post Code 7 Alphanumeric (1 of 6 patterns)
Reserved 6 Spaces
Customer Data 6, 45 or 29 Anything (Latin-1)

The 6 Destination+DPS (Destination Post Code plus Delivery Point Suffix) patterns are the same as for the 4-state - see Table : Royal Mail Mailmark Destination+DPS Patterns. The 6 RTS (Return to Sender) Post Code patterns are the same also except without the additional DPS 'NL', i.e.

Table : Royal Mail 2D Mailmark RTS Patterns
FNFNLLS FFNNLLS FFNNNLL
FFNFNLL FNNLLSS FNNNLLS

where 'F' is full alphabetic (A-Z), 'L' limited alphabetic (A-Z less 'CIKMOV'), 'N' numeric (0-9), and 'S' space.

Three sizes are defined, one rectangular, with varying maximum amounts of optional customer data:

Table : Royal Mail 2D Mailmark Sizes
Name Size Customer Data Zint Version
Type 7 24 x 24 6 characters 8
Type 9 32 x 32 45 characters 10
Type 29 16 x 48 29 characters 30

Zint will automatically select a size based on the amount of customer data, or it can be specified using the --vers option (API option_2), which takes the Zint version number (one more than the Royal Mail Type number). Zint will prefix the input data with "JGB " if it’s missing, and also space-pad the input if the customer data is absent or falls short. As with Data Matrix, the rectangular symbol Type 29 can be excluded from automatic size selection by using the option --square (API option_3 = DM_SQUARE).

GS1 data, the ECI mechanism, and Structured Append are not supported.

6.6.3 QR Code (ISO 18004)

zint -b QRCODE -d "QR Code Symbol" --mask=5

Also known as Quick Response Code this symbology was developed by Denso. Four levels of error correction are available using the --secure option (API option_1) as shown in the following table.

Table : QR Code ECC Levels
Input ECC Level Error Correction Capacity Recovery Capacity
1 L Approx 20% of symbol Approx 7%
2 M Approx 37% of symbol Approx 15%
3 Q Approx 55% of symbol Approx 25%
4 H Approx 65% of symbol Approx 30%

The size of the symbol can be specified by setting the --vers option (API option_2) to the QR Code version required (1-40). The size of symbol generated is shown in the table below.

Table : QR Code Sizes
Input Symbol Size Input Symbol Size Input Symbol Size
1 21 x 21 15 77 x 77 29 133 x 133
2 25 x 25 16 81 x 81 30 137 x 137
3 29 x 29 17 85 x 85 31 141 x 141
4 33 x 33 18 89 x 89 32 145 x 145
5 37 x 37 19 93 x 93 33 149 x 149
6 41 x 41 20 97 x 97 34 153 x 153
7 45 x 45 21 101 x 101 35 157 x 157
8 49 x 49 22 105 x 105 36 161 x 161
9 53 x 53 23 109 x 109 37 165 x 165
10 57 x 57 24 113 x 113 38 169 x 169
11 61 x 61 25 117 x 117 39 173 x 173
12 65 x 65 26 121 x 121 40 177 x 177
13 69 x 69 27 125 x 125
14 73 x 73 28 129 x 129

The maximum capacity of a QR Code symbol (version 40) is 7089 numeric digits, 4296 alphanumeric characters or 2953 bytes of data. QR Code symbols can also be used to encode GS1 data. QR Code symbols can by default encode either characters in the Latin-1 set or Kanji, Katakana and ASCII characters which are members of the Shift JIS encoding scheme. In addition QR Code supports other character sets using the ECI mechanism. Input should usually be entered as UTF-8 with conversion to Latin-1 or Shift JIS being carried out by Zint. A separate symbology ID (BARCODE_HIBC_QR) can be used to encode Health Industry Barcode (HIBC) data.

Non-ASCII data density may be maximized by using the --fullmultibyte switch (API option_3 = ZINT_FULL_MULTIBYTE), but check that your barcode reader supports this before using.

QR Code has eight different masks designed to minimize unwanted patterns. The best mask to use is selected automatically by Zint but may be manually specified by using the --mask switch with values 0-7, or in the API by setting option_3 = (N + 1) << 8 where N is 0-7. To use with ZINT_FULL_MULTIBYTE set

option_3 = ZINT_FULL_MULTIBYTE | (N + 1) << 8

The --fast option (API input_mode |= FAST_MODE) may be used when leaving Zint to automatically select a mask to reduce the number of masks to try to four (0, 2, 4, 7).

QR Code supports Structured Append of up to 16 symbols and a numeric ID (parity), which can be set by using the --structapp option (see 4.17 Structured Append) (API structapp). The parity ID ranges from 0 (default) to 255, and for full compliance should be set to the value obtained by XOR-ing together each byte of the complete data forming the sequence. Currently this calculation must be done outside of Zint.

6.6.4 Micro QR Code (ISO 18004)

zint -b MICROQR -d "01234567"

A miniature version of the QR Code symbol for short messages, Micro QR Code symbols can encode either Latin-1 characters or Shift JIS characters. Input should be entered as a UTF-8 stream with conversion to Latin-1 or Shift JIS being carried out automatically by Zint. A preferred symbol size can be selected by using the --vers option (API option_2), as shown in the table below. Note that versions M1 and M2 have restrictions on what characters can be encoded.

Table : Micro QR Code Sizes
Input Version Symbol Size Allowed Characters
1 M1 11 x 11 Numeric only
2 M2 13 x 13 Numeric, uppercase letters, space, and the characters "$%*+-./:"
3 M3 15 x 15 Latin-1 and Shift JIS
4 M4 17 x 17 Latin-1 and Shift JIS

Version M4 can encode up to 35 digits, 21 alphanumerics, 15 bytes or 9 Kanji characters.

Except for version M1, which is always ECC level L, the amount of ECC codewords can be adjusted using the --secure option (API option_1); however ECC level H is not available for any version, and ECC level Q is only available for version M4:

Table : Micro QR ECC Levels
Input ECC Level Error Correction Capacity Recovery Capacity Available for Versions
1 L Approx 20% of symbol Approx 7% M1, M2, M3, M4
2 M Approx 37% of symbol Approx 15% M2, M3, M4
3 Q Approx 55% of symbol Approx 25% M4

The defaults for symbol size and ECC level depend on the input and whether either of them is specified.

For barcode readers that support it, non-ASCII data density may be maximized by using the --fullmultibyte switch (API option_3 = ZINT_FULL_MULTIBYTE).

Micro QR Code has four different masks designed to minimize unwanted patterns. The best mask to use is selected automatically by Zint but may be manually specified by using the --mask switch with values 0-3, or in the API by setting option_3 = (N + 1) << 8 where N is 0-3. To use with ZINT_FULL_MULTIBYTE set

option_3 = ZINT_FULL_MULTIBYTE | (N + 1) << 8

6.6.5 Rectangular Micro QR Code (rMQR) (ISO 23941)

zint -b RMQR -d "0123456"

A rectangular version of QR Code, rMQR supports encoding of GS1 data, and either Latin-1 characters or Shift JIS characters, and other encodings using the ECI mechanism. As with other symbologies data should be entered as UTF-8 with conversion being handled by Zint. The amount of ECC codewords can be adjusted using the --secure option (API option_1), however only ECC levels M and H are valid for this type of symbol.

Table : rMQR ECC Levels
Input ECC Level Error Correction Capacity Recovery Capacity
2 M Approx 37% of symbol Approx 15%
4 H Approx 65% of symbol Approx 30%

The preferred symbol sizes can be selected using the --vers option (API option_2) as shown in the table below. Input values between 33 and 38 fix the height of the symbol while allowing Zint to determine the minimum symbol width.

Table : rMQR Sizes
Input Version Symbol Size (HxW) Input Version Symbol Size (HxW)
1 R7x43 7 x 43 20 R13x77 13 x 77
2 R7x59 7 x 59 21 R13x99 13 x 99
3 R7x77 7 x 77 22 R13x139 13 x 139
4 R7x99 7 x 99 23 R15x43 15 x 43
5 R7x139 7 x 139 24 R15x59 15 x 59
6 R9x43 9 x 43 25 R15x77 15 x 77
7 R9x59 9 x 59 26 R15x99 15 x 99
8 R9x77 9 x 77 27 R15x139 15 x 139
9 R9x99 9 x 99 28 R17x43 17 x 43
10 R9x139 9 x 139 29 R17x59 17 x 59
11 R11x27 11 x 27 30 R17x77 17 x 77
12 R11x43 11 x 43 31 R17x99 17 x 99
13 R11x59 11 x 59 32 R17x139 17 x 139
14 R11x77 11 x 77 33 R7xW 7 x automatic width
15 R11x99 11 x 99 34 R9xW 9 x automatic width
16 R11x139 11 x 139 35 R11xW 11 x automatic width
17 R13x27 13 x 27 36 R13xW 13 x automatic width
18 R13x43 13 x 43 37 R15xW 15 x automatic width
19 R13x59 13 x 59 38 R17xW 17 x automatic width

The largest version R17x139 (32) can encode up to 361 digits, 219 alphanumerics, 150 bytes, or 92 Kanji characters.

For barcode readers that support it, non-ASCII data density may be maximized by using the --fullmultibyte switch or in the API by setting option_3 = ZINT_FULL_MULTIBYTE.

6.6.6 UPNQR (Univerzalnega Plačilnega Naloga QR)

zint -b UPNQR -i upn_utf8.txt --quietzones

A variation of QR Code used by Združenje Bank Slovenije (Bank Association of Slovenia). The size, error correction level and ECI are set by Zint and do not need to be specified. UPNQR is unusual in that it uses Latin-2 (ISO/IEC 8859-2 plus ASCII) formatted data. Zint will accept UTF-8 data and convert it to Latin-2, or if your data is already Latin-2 formatted use the --binary switch (API input_mode = DATA_MODE).

The following example creates a symbol from data saved as a Latin-2 file:

zint -o upnqr.png -b 143 --scale=3 --binary -i upn.txt

A mask may be manually specified or the --fast option used as with QRCODE.

6.6.7 MaxiCode (ISO 16023)

zint -b MAXICODE -d "1Z00004951\GUPSN\G06X610\G159\G1234567\G1/1\G\GY\G1 MAIN ST\GNY\GNY\R\E" --esc --primary="152382802000000" --scmvv=96

Developed by UPS the MaxiCode symbology employs a grid of hexagons surrounding a bullseye finder pattern. This symbology is designed for the identification of parcels. MaxiCode symbols can be encoded in one of five modes. In modes 2 and 3 MaxiCode symbols are composed of two parts named the primary and secondary messages. The primary message consists of a Structured Carrier Message which includes various data about the package being sent and the secondary message usually consists of address data in a data structure. The format of the primary message required by Zint is given in the following table.

Table : MaxiCode Structured Carrier Message Format:
Characters Meaning
1 - 9 Postcode data which can consist of up to 9 digits (for mode 2)
or up to 6 alphanumeric characters (for mode 3). Remaining
unused characters for mode 3 can be filled with the SPACE
character (ASCII 32) or omitted.
(adjust the following character positions according to postcode
length)
10 - 12 Three-digit country code according to ISO 3166-1.
13 - 15 Three-digit service code. This depends on your parcel courier.

The primary message can be set at the command prompt using the --primary switch (API primary). The secondary message uses the normal data entry method. For example:

zint -o test.eps -b 57 --primary="999999999840012" \
    -d "Secondary Message Here"

When using the API the primary message must be placed in the primary string. The secondary is entered in the same way as described in 5.2 Encoding and Saving to File. When either of these modes is selected Zint will analyse the primary message and select either mode 2 or mode 3 as appropriate.

As a convenience the secondary message for modes 2 and 3 can be set to be prefixed by the ISO/IEC 15434 Format "01" (transportation) sequence "[)>\R01\Gvv", where vv is a 2-digit version, by using the --scmvv switch (API option_2 = vv + 1). For example to use the common version "96" (ASC MH10/SC 8):

zint -b 57 --primary="152382802840001" --scmvv=96 --esc -d \
  "1Z00004951\GUPSN\G06X610\G159\G1234567\G1/1\G\GY\G1 MAIN ST\GNY\GNY\R\E"

will prefix "[)>\R01\G96" to the secondary message. (\R, \G and \E are the escape sequences for Record Separator, Group Separator and End of Transmission respectively - see Table : Escape Sequences.)

Modes 4 to 6 can be accessed using the --mode switch (API option_1). Modes 4 to 6 do not have a primary message. For example:

zint -o test.eps -b 57 --mode=4 -d "A MaxiCode Message in Mode 4"

Mode 6 is reserved for the maintenance of scanner hardware and should not be used to encode user data.

This symbology uses Latin-1 character encoding by default but also supports the ECI encoding mechanism. The maximum length of text which can be placed in a MaxiCode symbol depends on the type of characters used in the text.

Example maximum data lengths are given in the table below:

Table : MaxiCode Data Length Maxima
Mode Maximum Data Length for Capital Letters Maximum Data Length for Numeric Digits Number of Error Correction Codewords
2* 84 126 50
3* 84 126 50
4 93 138 50
5 77 113 66
6 93 138 50

* - secondary only

MaxiCode supports Structured Append of up to 8 symbols, which can be set by using the --structapp option (see 4.17 Structured Append) (API structapp). It does not support specifying an ID.

MaxiCode uses a different scaling than other symbols for raster output, see 4.9.3 MaxiCode Raster Scaling, and also for EMF vector output, when the scale is multiplied by 20 instead of 2.

6.6.8 Aztec Code (ISO 24778)

zint -b AZTEC -d "123456789012"

Invented by Andrew Longacre at Welch Allyn Inc in 1995 the Aztec Code symbol is a matrix symbol with a distinctive bullseye finder pattern. Zint can generate Compact Aztec Code (sometimes called Small Aztec Code) as well as ‘full-range’ Aztec Code symbols and by default will automatically select symbol type and size dependent on the length of the data to be encoded. Error correction codewords will normally be generated to fill at least 23% of the symbol. Two options are available to change this behaviour:

The size of the symbol can be specified using the --vers option (API option_2) to a value between 1 and 36 according to the following table. The symbols marked with an asterisk (*) in the table below are ‘compact’ symbols, meaning they have a smaller bullseye pattern at the centre of the symbol.

Table : Aztec Code Sizes
Input Symbol Size Input Symbol Size Input Symbol Size
1 15 x 15* 13 53 x 53 25 105 x 105
2 19 x 19* 14 57 x 57 26 109 x 109
3 23 x 23* 15 61 x 61 27 113 x 113
4 27 x 27* 16 67 x 67 28 117 x 117
5 19 x 19 17 71 x 71 29 121 x 121
6 23 x 23 18 75 x 75 30 125 x 125
7 27 x 27 19 79 x 79 31 131 x 131
8 31 x 31 20 83 x 83 32 135 x 135
9 37 x 37 21 87 x 87 33 139 x 139
10 41 x 41 22 91 x 91 34 143 x 143
11 45 x 45 23 95 x 95 35 147 x 147
12 49 x 49 24 101 x 101 36 151 x 151

Note that in symbols which have a specified size the amount of error correction is dependent on the length of the data input and Zint will allow error correction capacities as low as 3 codewords.

Alternatively the amount of error correction data can be specified by setting the --secure option (API option_1) to a value from the following table.

Table : Aztec Code Error Correction Modes
Mode Error Correction Capacity
1 >10% + 3 codewords
2 >23% + 3 codewords
3 >36% + 3 codewords
4 >50% + 3 codewords

It is not possible to select both symbol size and error correction capacity for the same symbol. If both options are selected then the error correction capacity selection will be ignored.

Aztec Code supports ECI encoding and can encode up to a maximum length of approximately 3823 numeric or 3067 alphabetic characters or 1914 bytes of data. A separate symbology ID (BARCODE_HIBC_AZTEC) can be used to encode Health Industry Barcode (HIBC) data.

Aztec Code supports Structured Append of up to 26 symbols and an optional alphanumeric ID of up to 32 characters, which can be set by using the --structapp option (see 4.17 Structured Append) (API structapp). The ID cannot contain spaces. If an ID is not given, no ID is encoded.

6.6.9 Aztec Runes (ISO 24778)

zint -b AZRUNE -d "125"

A truncated version of compact Aztec Code for encoding whole integers between 0 and 255, as defined in ISO/IEC 24778 Annex A. Includes Reed-Solomon error correction. It does not support Structured Append.

6.6.10 Code One

zint -b CODEONE -d "1234567890123456789012"

A matrix symbology developed by Ted Williams in 1992 which encodes data in a way similar to Data Matrix, Code One is able to encode the Latin-1 character set or GS1 data, and also supports the ECI mechanism. There are two types of Code One symbol - fixed-ratio symbols which are roughly square (versions A through to H) and variable-width versions (versions S and T). These can be selected by using --vers (API option_2) as shown in the table below:

Table : Code One Sizes
Input Version Size (W x H) Numeric Data Capacity Alphanumeric Data Capacity
1 A 16 x 18 22 13
2 B 22 x 22 44 27
3 C 28 x 28 104 64
4 D 40 x 42 217 135
5 E 52 x 54 435 271
6 F 70 x 76 886 553
7 G 104 x 98 1755 1096
8 H 148 x 134 3550 2218
9 S width x 8 18 N/A
10 T width x 16 90 55

Version S symbols can only encode numeric data. The width of version S and version T symbols is determined by the length of the input data.

Code One supports Structured Append of up to 128 symbols, which can be set by using the --structapp option (see 4.17 Structured Append) (API structapp). It does not support specifying an ID. Structured Append is not supported with GS1 data nor for Version S symbols.

6.6.11 Grid Matrix

zint -b GRIDMATRIX --eci=29 -d "AAT2556 电池充电器+降压转换器  200mA至2A tel:86 019 82512738"

Grid Matrix groups modules in a chequerboard pattern, and by default supports the GB 2312 standard set, which includes Hanzi, ASCII and a small number of ISO/IEC 8859-1 characters. Input should be entered as UTF-8 with conversion to GB 2312 being carried out automatically by Zint. Up to around 1529 alphanumeric characters or 2751 digits may be encoded. The symbology also supports the ECI mechanism. Support for GS1 data has not yet been implemented.

The size of the symbol and the error correction capacity can be specified. If you specify both of these values then Zint will make a ‘best-fit’ attempt to satisfy both conditions. The symbol size can be specified using the --vers option (API option_2), and the error correction capacity can be specified by using the --secure option (API option_1), according to the following tables.

Table : Grid Matrix Sizes
Input Symbol Size Input Symbol Size
1 18 x 18 8 102 x 102
2 30 x 30 9 114 x 114
3 42 x 42 10 126 x 126
4 54 x 54 11 138 x 138
5 66 x 66 12 150 x 150
6 78 x 78 13 162 x 162
7 90 x 90
Table : Grid Matrix Error Correction Modes
Mode Error Correction Capacity
1 Approximately 10%
2 Approximately 20%
3 Approximately 30%
4 Approximately 40%
5 Approximately 50%

Non-ASCII data density may be maximized by using the --fullmultibyte switch (API option_3 = ZINT_FULL_MULTIBYTE), but check that your barcode reader supports this before using.

Grid Matrix supports Structured Append of up to 16 symbols and a numeric ID (file signature), which can be set by using the --structapp option (see 4.17 Structured Append) (API structapp). The ID ranges from 0 (default) to 255.

6.6.12 DotCode

zint -b DOTCODE -d "[01]00012345678905[17]201231[10]ABC123456" --gs1

DotCode uses a grid of dots in a rectangular formation to encode characters up to a maximum of approximately 450 characters (or 900 numeric digits). The symbology supports ECI encoding and GS1 data encoding. By default Zint will produce a symbol which is approximately square, however the width of the symbol can be adjusted by using the --cols option (API option_2) (maximum 200). Outputting DotCode to raster images (BMP, GIF, PCX, PNG, TIF) will require setting the scale of the image to a larger value than the default (e.g. approximately 10) for the dots to be plotted correctly. Approximately 33% of the resulting symbol is comprised of error correction codewords.

DotCode has two sets of 4 masks, designated 0-3 and 0’-3’, the second "prime" set being the same as the first with corners lit. The best mask to use is selected automatically by Zint but may be manually specified by using the --mask switch with values 0-7, where 4-7 denote 0’-3’, or in the API by setting option_3 = (N + 1) << 8 where N is 0-7.

DotCode supports Structured Append of up to 35 symbols, which can be set by using the --structapp option (see 4.17 Structured Append) (API structapp). It does not support specifying an ID.

6.6.13 Han Xin Code (ISO 20830)

zint -b HANXIN -d "Hanxin Code symbol"

Also known as Chinese Sensible Code, Han Xin is capable of encoding characters in either the Latin-1 character set or the GB 18030 character set (which is a UTF, i.e. includes all Unicode characters, optimized for Chinese characters) and is also able to support the ECI mechanism. Support for the encoding of GS1 data has not yet been implemented.

The size of the symbol can be specified using the --vers option (API option_2) to a value between 1 and 84 according to the following table.

Table : Han Xin Sizes
Input Symbol Size Input Symbol Size Input Symbol Size
1 23 x 23 29 79 x 79 57 135 x 135
2 25 x 25 30 81 x 81 58 137 x 137
3 27 x 27 31 83 x 83 59 139 x 139
4 29 x 29 32 85 x 85 60 141 x 141
5 31 x 31 33 87 x 87 61 143 x 143
6 33 x 33 34 89 x 89 62 145 x 145
7 35 x 35 35 91 x 91 63 147 x 147
8 37 x 37 36 93 x 93 64 149 x 149
9 39 x 39 37 95 x 95 65 151 x 151
10 41 x 41 38 97 x 97 66 153 x 153
11 43 x 43 39 99 x 99 67 155 x 155
12 45 x 45 40 101 x 101 68 157 x 157
13 47 x 47 41 103 x 103 69 159 x 159
14 49 x 49 42 105 x 105 70 161 x 161
15 51 x 51 43 107 x 107 71 163 x 163
16 53 x 53 44 109 x 109 72 165 x 165
17 55 x 55 45 111 x 111 73 167 x 167
18 57 x 57 46 113 x 113 74 169 x 169
19 59 x 59 47 115 x 115 75 171 x 171
20 61 x 61 48 117 x 117 76 173 x 173
21 63 x 63 49 119 x 119 77 175 x 175
22 65 x 65 50 121 x 121 78 177 x 177
23 67 x 67 51 123 x 123 79 179 x 179
24 69 x 69 52 125 x 125 80 181 x 181
25 71 x 71 53 127 x 127 81 183 x 183
26 73 x 73 54 129 x 129 82 185 x 185
27 75 x 75 55 131 x 131 83 187 x 187
28 77 x 77 56 133 x 133 84 189 x 189

The largest version (84) can encode 7827 digits, 4350 ASCII characters, up to 2175 Chinese characters, or 3261 bytes, making it the most capacious of all the barcodes supported by Zint.

There are four levels of error correction capacity available for Han Xin Code which can be set by using the --secure option (API option_1) to a value from the following table.

Table : Han Xin Error Correction Modes
Mode Recovery Capacity
1 Approx 8%
2 Approx 15%
3 Approx 23%
4 Approx 30%

Non-ASCII data density may be maximized by using the --fullmultibyte switch (API option_3 = ZINT_FULL_MULTIBYTE), but check that your barcode reader supports this before using.

Han Xin has four different masks designed to minimize unwanted patterns. The best mask to use is selected automatically by Zint but may be manually specified by using the --mask switch with values 0-3, or in the API by setting option_3 = (N + 1) << 8 where N is 0-3. To use with ZINT_FULL_MULTIBYTE set

option_3 = ZINT_FULL_MULTIBYTE | (N + 1) << 8

6.6.14 Ultracode

zint -b ULTRA -d "HEIMASÍÐA KENNARAHÁSKÓLA ÍSLANDS"

This symbology uses a grid of coloured elements to encode data. ECI and GS1 modes are supported. The amount of error correction can be set using the --secure option (API option_1) to a value as shown in the following table.

Table : Ultracode Error Correction Values
Value EC Level Amount of symbol holding error correction data
1 EC0 0% - Error detection only
2 EC1 Approx 5%
3 EC2 Approx 9% - Default value
4 EC3 Approx 17%
5 EC4 Approx 25%
6 EC5 Approx 33%

Zint does not currently implement data compression by default, but this can be initiated through the API by setting

symbol->option_3 = ULTRA_COMPRESSION;

With compression, up to 504 digits, 375 alphanumerics or 252 bytes can be encoded.

Revision 2 of Ultracode (2023) may be specified using --vers=2 (API option_2 = 2).


WARNING: Revision 2 of Ultracode was only finalized December 2023 and Zint has not yet been updated to support it. Do not use.


Ultracode supports Structured Append of up to 8 symbols and an optional numeric ID (File Number), which can be set by using the --structapp option (see 4.17 Structured Append) (API structapp). The ID ranges from 1 to 80088. If an ID is not given, no ID is encoded.

6.7 Other Barcode-Like Markings

6.7.1 Facing Identification Mark (FIM)

zint -b FIM --compliantheight -d "C"

Used by the United States Postal Service (USPS), the FIM symbology is used to assist automated mail processing. There are only 5 valid symbols which can be generated using the characters A-E as shown in the table below.

Table : Valid FIM Characters
Code Letter Usage
A Used for courtesy reply mail and metered reply mail with a
pre-printed POSTNET symbol.
B Used for business reply mail without a pre-printed zip code.
C Used for business reply mail with a pre-printed zip code.
D Used for Information Based Indicia (IBI) postage.
E Used for customized mail with a USPS Intelligent Mail barcode.

6.7.2 Flattermarken

zint -b FLAT -d "1304056"

Used for the recognition of page sequences in print-shops, the Flattermarken is not a true barcode symbol and requires precise knowledge of the position of the mark on the page. The Flattermarken system can encode numeric data up to a maximum of 128 digits and does not include a check digit.

7. Legal and Version Information

7.1 License

Zint, libzint and Zint Barcode Studio are Copyright © 2024 Robin Stuart. All historical versions are distributed under the GNU General Public License version 3 or later. Versions 2.5 and later are released under a dual license: the encoding library is released under the BSD (3 clause) license whereas the GUI, Zint Barcode Studio, and the CLI are released under the GNU General Public License version 3 or later.

Telepen is a trademark of SB Electronic Systems Ltd.

QR Code is a registered trademark of Denso Wave Incorporated.

Mailmark is a registered trademark of Royal Mail Group Ltd.

Microsoft, Windows and the Windows logo are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.

Linux is the registered trademark of Linus Torvalds in the U.S. and other countries.

Mac and macOS are trademarks of Apple Inc., registered in the U.S. and other countries.

The Zint logo is derived from “SF Planetary Orbiter” font by ShyFoundary.

Zint.org.uk website design and hosting provided by Robert Elliott.

7.2 Patent Issues

All of the code in Zint is developed using information in the public domain, usually freely available on the Internet. Some of the techniques used may be subject to patents and other intellectual property legislation. It is my belief that any patents involved in the technology underlying symbologies utilised by Zint are ‘unadopted’, that is the holder does not object to their methods being used.

Any methods patented or owned by third parties or trademarks or registered trademarks used within Zint or in this document are and remain the property of their respective owners and do not indicate endorsement or affiliation with those owners, companies or organisations.

7.3 Version Information

The current stable version of Zint is 2.13.0, released on 18th December 2023.

See "ChangeLog" in the project root directory for information on all releases.

7.4 Sources of Information

Below is a list of some of the sources used in rough chronological order:

7.5 Standards Compliance

Zint was developed to provide compliance with the following British and international standards:

7.5.1 Symbology Standards

A number of other specification documents have also been referenced, such as MIL-STD-1189 Rev. B (1989) (LOGMARS), USPS DMM 300 2006 (2011) (POSTNET, PLANET, FIM) and USPS-B-3200 (2015) (IMAIL). Those not named include postal and delivery company references in particular.

7.5.2 General Standards

Annex A. Character Encoding

This section is intended as a quick reference to the character sets used by Zint. All symbologies use standard ASCII input as shown in section A.1, but some support extended characters as shown in the subsequent section A.2 Latin Alphabet No. 1 (ISO/IEC 8859-1).

A.1 ASCII Standard

The ubiquitous ASCII standard is well known to most computer users. It’s reproduced here for reference.

Table : ASCII
Hex 0 1 2 3 4 5 6 7
0 NUL DLE SPACE 0 @ P ` p
1 SOH DC1 ! 1 A Q a q
2 STX DC2 " 2 B R b r
3 ETX DC3 # 3 C S c s
4 EOT DC4 $ 4 D T d t
5 ENQ NAK % 5 E U e u
6 ACK SYN & 6 F V f v
7 BEL ETB ' 7 G W g w
8 BS CAN ( 8 H X h x
9 TAB EM ) 9 I Y i y
A LF SUB * : J Z j z
B VT ESC + ; K [ k {
C FF FS , < L \ l |
D CR GS - = M ] m }
E SO RS . > N ^ n ~
F SI US / ? O _ o DEL

A.2 Latin Alphabet No. 1 (ISO/IEC 8859-1)

ISO/IEC 8859-1 defines additional characters common in western European languages like French, German, Italian and Spanish. This extension is the default encoding of many barcodes (see Table : Default Character Sets) when a codepoint above hex 9F is encoded. Note that codepoints hex 80 to 9F are not defined.

Table : ISO/IEC 8859-1
Hex 8 9 A B C D E F
0 NBSP ° À Ð à ð
1 ¡ ± Á Ñ á ñ
2 ¢ ² Â Ò â ò
3 £ ³ Ã Ó ã ó
4 ¤ ´ Ä Ô ä ô
5 ¥ μ Å Õ å õ
6 ¦ Æ Ö æ ö
7 § · Ç × ç ÷
8 ¨ ¸ È Ø è ø
9 © ¹ É Ù é ù
A ª º Ê Ú ê ú
B « » Ë Û ë û
C ¬ ¼ Ì Ü ì ü
D SHY ½ Í Ý í ý
E ® ¾ Î Þ î þ
F ¯ ¿ Ï ß ï ÿ

Annex B. Qt Backend QZint

Used internally by Zint Barcode Studio to display the preview, the Qt Backend QZint renders a barcode by drawing the vector representation (see 5.5 Buffering Symbols in Memory (vector)) provided by the Zint library libzint.

The main class is Zint::QZint, which has getter/setter properties that correspond to the zint_symbol structure (see 5.7 Setting Options), and a main method render() which takes a Qt QPainter to paint with, and a QRectF rectangular area specifying where to paint into:

/* Encode and display barcode in `paintRect` using `painter`.
   Note: legacy argument `mode` is not used */
void render(QPainter& painter, const QRectF& paintRect,
            AspectRatioMode mode = IgnoreAspectRatio);

render() will emit one of two Qt signals - encoded on successful encoding and drawing, or errored on failure. The client can connect and act appropriately, for instance:

connect(qzint, SIGNAL(encoded()), SLOT(on_encoded()));
connect(qzint, SIGNAL(errored()), SLOT(on_errored()));

where qzint is an instance of Zint::QZint and on_encoded() and on_error() are Qt slot methods provided by the caller. On error, the error value and message can be retrieved by the methods getError() and lastError() respectively.

The other main method is save_to_file():

/* Encode and print barcode to file `filename`.
   Only sets `getError()` on error, not on warning */
bool save_to_file(const QString& filename); // `ZBarcode_Print()`

which takes a filename to output to. It too will emit an errored signal on failure, returning false (but nothing on success, which just returns true). Note that rotation is achieved through the setter method setRotateAngleValue() (as opposed to the rotate_angle argument used by ZBarcode_Print()).

Various other methods are available, for instance methods for testing symbology capabilities, and utility methods such as defaultXdim() and getAsCLI().

For full details, see "backend_qt/qzint.h".

Annex C. Tcl Backend Binding

A Tcl binding is available in the "backend_tcl” sub-directory. To make on Unix:

cd backend_tcl
autoconf
./configure
make
sudo make install

For Windows, a Visual Studio 6.0 project file is available at "backend_tcl\zint_tcl.dsp". This can also be opened (and converted) by more modern Visual Studio versions, though some fixing up of the project configuration will likely be required.

Once built and installed, invoke the Tcl/Tk CLI "wish":

wish

and ignoring the Tk window click back to the command prompt "%" and type:

require package zint
zint help

which will show the usage message, with options very similiar to the Zint CLI. (One notable difference is that boolean options such as -bold take a 1 or 0 as an argument.)

A demonstration Tcl/Tk program which is also useful in itself is available at "backend_tcl/demo/demo.tcl". To run type:

wish demo/demo.tcl

which will display the following window.

Tcl/Tk demonstration program window

You can select the symbology, enter the data to encode, and set options (which are the same as those given in the usage message). A raster preview of the configured barcode is displayed once the "Generate" button is pressed.

Annex D. Man Page ZINT(1)

NAME

zint - encode data as a barcode image

SYNOPSIS

zint [-h | --help]
zint [options]

DESCRIPTION

zint takes input data from the command line or a file to encode in a barcode which is then output to an image file.

Input data is UTF-8, unless --binary is specified.

Human Readable Text (HRT) is displayed by default for those barcodes that support HRT, unless --notext is specified.

The output image file (specified with -o | --output) may be in one of these formats: Windows Bitmap (BMP), Enhanced Metafile Format (EMF), Encapsulated PostScript (EPS), Graphics Interchange Format (GIF), ZSoft Paintbrush (PCX), Portable Network Format (PNG), Scalable Vector Graphic (SVG), or Tagged Image File Format (TIF).

OPTIONS

-h, --help

Print usage information summarizing command line options.

-b TYPE, --barcode=TYPE

Set the barcode symbology that will be used to encode the data. TYPE is the number or name of the barcode symbology. If not given, the symbology defaults to 20 (Code 128). To see what types are available, use the -t | --types option. Type names are case-insensitive, and non-alphanumerics are ignored.

--addongap=INTEGER

For EAN/UPC symbologies, set the gap between the main data and the add-on. INTEGER is in integral multiples of the X-dimension. The maximum gap that can be set is 12. The minimum is 7, except for UPC-A, when the minimum is 9.

--batch

Treat each line of an input file specified with -i | --input as a separate data set and produce a barcode image for each one. The barcode images are outputted by default to numbered filenames starting with “00001.png”, “00002.png” etc., which can be changed by using the -o | --output option.

--bg=COLOUR

Specify a background (paper) colour where COLOUR is in hexadecimal RRGGBB or RRGGBBAA format or in decimal C,M,Y,K percentages format.

--binary

Treat input data as raw 8-bit binary data instead of the default UTF-8. Automatic code page translation to an ECI page is disabled, and no validation of the data’s character encoding takes place.

--bind

Add horizontal boundary bars (also known as bearer bars) to the symbol. The width of the boundary bars is specified by the --border option. --bind can also be used to add row separator bars to symbols stacked with multiple -d | --data inputs, in which case the width of the separator bars is specified with the --separator option.

--bindtop

Add a horizontal boundary bar to the top of the symbol. The width of the boundary bar is specified by the --border option.

--bold

Use a bold font for the Human Readable Text (HRT).

--border=INTEGER

Set the width of boundary bars (--bind or --bindtop) or box borders (--box), where INTEGER is in integral multiples of the X-dimension. The default is zero.

--box

Add a box around the symbol. The width of the borders is specified by the --border option.

--cmyk

Use the CMYK colour space when outputting to Encapsulated PostScript (EPS) or TIF files.

--cols=INTEGER

Set the number of data columns in the symbol to INTEGER. Affects Codablock-F, DotCode, GS1 DataBar Expanded Stacked (DBAR_EXPSTK), MicroPDF417 and PDF417 symbols.

--compliantheight

Warn if the height specified by the --height option is not compliant with the barcode’s specification, or if --height is not given, default to the height specified by the specification (if any).

-d, --data=DATA

Specify the input DATA to encode. The --esc option may be used to enter non-printing characters using escape sequences. The DATA should be UTF-8, unless the --binary option is given, in which case it can be anything.

--direct

Send output to stdout, which in most cases should be re-directed to a pipe or a file. Use --filetype to specify output format.

--dmiso144

For Data Matrix symbols, use the standard ISO/IEC codeword placement for 144 x 144 (--vers=24) sized symbols, instead of the default “de facto” placement (which rotates the placement of ECC codewords).

--dmre

For Data Matrix symbols, allow Data Matrix Rectangular Extended (DMRE) sizes when considering automatic sizes. See also --square.

--dotsize=NUMBER

Set the radius of the dots in dotty mode (--dotty). NUMBER is in X-dimensions, and may be floating-point. The default is 0.8.

--dotty

Use dots instead of squares for matrix symbols. DotCode is always in dotty mode.

--dump

Dump a hexadecimal representation of the symbol’s encodation to stdout. The same representation may be outputted to a file by using a .txt extension with -o | --output or by specifying --filetype=txt.

-e, --ecinos

Display the table of ECIs (Extended Channel Interpretations).

--eci=INTEGER

Set the ECI code for the input data to INTEGER. See -e | --ecinos for a list of the ECIs available. ECIs are supported by Aztec Code, Code One, Data Matrix, DotCode, Grid Matrix, Han Xin Code, MaxiCode, MicroPDF417, PDF417, QR Code, rMQR and Ultracode.

--embedfont

For vector output, embed the font in the file for portability. Currently only available for SVG output.

--esc

Process escape characters in the input data. The escape sequences are:

\0       (0x00)    NUL  Null character
\E       (0x04)    EOT  End of Transmission
\a       (0x07)    BEL  Bell
\b       (0x08)    BS   Backspace
\t       (0x09)    HT   Horizontal Tab
\n       (0x0A)    LF   Line Feed
\v       (0x0B)    VT   Vertical Tab
\f       (0x0C)    FF   Form Feed
\r       (0x0D)    CR   Carriage Return
\e       (0x1B)    ESC  Escape
\G       (0x1D)    GS   Group Separator
\R       (0x1E)    RS   Record Separator
\\       (0x5C)    \    Backslash
\dNNN    (NNN)          Any 8-bit character where NNN is
                        decimal (000-255)
\oNNN    (0oNNN)        Any 8-bit character where NNN is
                        octal (000-377)
\xNN     (0xNN)         Any 8-bit character where NN is
                        hexadecimal (00-FF)
\uNNNN   (U+NNNN)       Any 16-bit Unicode BMP character
                        where NNNN is hexadecimal
\UNNNNNN (U+NNNNNN)     Any 21-bit Unicode character
                        where NNNNNN is hexadecimal
--extraesc

For Code 128 only, process the special escape sequences \^A, \^B and \^C that allow manual switching of Code Sets, and the special escape sequence \^1 that inserts an FNC1 character. The sequence \^^ can be used to encode data that contains special escape sequences.

--fast

Use faster if less optimal encodation or other shortcuts (affects Data Matrix, MicroPDF417, PDF417, QRCODE & UPNQR only).

--fg=COLOUR

Specify a foreground (ink) colour where COLOUR is in hexadecimal RRGGBB or RRGGBBAA format or in decimal C,M,Y,K percentages format.

--filetype=TYPE

Set the output file type to TYPE, which is one of BMP, EMF, EPS, GIF, PCX, PNG, SVG, TIF, TXT.

--fullmultibyte

Use the multibyte modes of Grid Matrix, Han Xin and QR Code for non-ASCII data.

--gs1

Treat input as GS1 compatible data. Application Identifiers (AIs) should be placed in square brackets "[]" (but see --gs1parens).

--gs1nocheck

Do not check the validity of GS1 data.

--gs1parens

Process parentheses "()" as GS1 AI delimiters, rather than square brackets "[]". The input data must not otherwise contain parentheses.

--gssep

For Data Matrix in GS1 mode, use GS (0x1D) as the GS1 data separator instead of FNC1.

--guarddescent=NUMBER

For EAN/UPC symbols, set the height the guard bars descend below the main bars, where NUMBER is in X-dimensions. NUMBER may be floating-point.

--guardwhitespace

For EAN/UPC symbols, add quiet zone indicators "<" and/or ">" to HRT where applicable.

--height=NUMBER

Set the height of the symbol in X-dimensions. NUMBER may be floating-point.

--heightperrow

Treat height as per-row. Affects Codablock-F, Code 16K, Code 49, GS1 DataBar Expanded Stacked (DBAR_EXPSTK), MicroPDF417 and PDF417.

-i, --input=FILE

Read the input data from FILE. Specify a single hyphen (-) for FILE to read from stdin.

--init

Create a Reader Initialisation (Programming) symbol.

--mask=INTEGER

Set the masking pattern to use for DotCode, Han Xin or QR Code to INTEGER, overriding the automatic selection.

--mirror

Use the batch data to determine the filename in batch mode (--batch). The -o | --output option can be used to specify an output directory (any filename will be ignored).

--mode=INTEGER

For MaxiCode and GS1 Composite symbols, set the encoding mode to INTEGER.

For MaxiCode (SCM is Structured Carrier Message, with 3 fields: postcode, 3-digit ISO 3166-1 country code, 3-digit service code):

2   SCM with 9-digit numeric postcode
3   SCM with 6-character alphanumeric postcode
4   Enhanced ECC for the primary part of the message
5   Enhanced ECC for all of the message
6   Reader Initialisation (Programming)

For GS1 Composite symbols (names end in _CC, i.e. EANX_CC, GS1_128_CC, DBAR_OMN_CC etc.):

1   CC-A
2   CC-B
3   CC-C (GS1_128_CC only)
--nobackground

Remove the background colour (EMF, EPS, GIF, PNG, SVG and TIF only).

--noquietzones

Disable any quiet zones for symbols that define them by default.

--notext

Remove the Human Readable Text (HRT).

-o, --output=FILE

Send the output to FILE. When not in batch mode, the default is “out.png” (or “out.gif” if zint built without PNG support). When in batch mode (--batch), special characters can be used to format the output filenames:

~           Insert a number or 0
#           Insert a number or space
@           Insert a number or * (+ on Windows)
Any other   Insert literally
--primary=STRING

For MaxiCode, set the content of the primary message. For GS1 Composite symbols, set the content of the linear symbol.

--quietzones

Add compliant quiet zones for symbols that specify them. This is in addition to any whitespace specified by -w | --whitesp or --vwhitesp.

-r, --reverse

Reverse the foreground and background colours (white on black). Known as “reflectance reversal” or “reversed reflectance”.

--rotate=INTEGER

Rotate the symbol by INTEGER degrees, where INTEGER can be 0, 90, 270 or 360.

--rows=INTEGER

Set the number of rows for Codablock-F or PDF417 to INTEGER. It will also set the minimum number of rows for Code 16K or Code 49, and the maximum number of rows for GS1 DataBar Expanded Stacked (DBAR_EXPSTK).

--scale=NUMBER

Adjust the size of the X-dimension. NUMBER may be floating-point, and is multiplied by 2 (except for MaxiCode) before being applied. The default scale is 1.

For MaxiCode, the scale is multiplied by 10 for raster output, by 40 for EMF output, and by 2 otherwise.

Increments of 0.5 (half-integers) are recommended for non-MaxiCode raster output (BMP, GIF, PCX, PNG and TIF).

See also --scalexdimdp below.

--scalexdimdp=X[,R]

Scale the image according to X-dimension X and resolution R, where X is in mm and R is in dpmm (dots per mm). X and R may be floating-point. R is optional and defaults to 12 dpmm (approximately 300 dpi). X may be zero in which case a symbology-specific default is used.

The scaling takes into account the output filetype, and deals with all the details mentioned above. Units may be specified for X by appending “in” (inch) or “mm”, and for R by appending “dpi” (dots per inch) or “dpmm” - e.g. --scalexdimdp=0.013in,300dpi.

--scmvv=INTEGER

For MaxiCode, prefix the Structured Carrier Message (SCM) with "[)>\R01\Gvv", where vv is a 2-digit INTEGER.

--secure=INTEGER

Set the error correction level (ECC) to INTEGER. The meaning is specific to the following matrix symbols (all except PDF417 are approximate):

Aztec Code  1 to 4 (10%, 23%, 36%, 50%)
Grid Matrix 1 to 5 (10% to 50%)
Han Xin     1 to 4 (8%, 15%, 23%, 30%)
Micro QR    1 to 3 (7%, 15%, 25%) (L, M, Q)
PDF417      0 to 8 (2^(INTEGER + 1) codewords)
QR Code     1 to 4 (7%, 15%, 25%, 30%) (L, M, Q, H)
rMQR        2 or 4 (15% or 30%) (M or H)
Ultracode   1 to 6 (0%, 5%, 9%, 17%, 25%, 33%)
--segN=ECI,DATA

Set the ECI & DATA content for segment N, where N is 1 to 9. -d | --data must still be given, and counts as segment 0, its ECI given by --eci. Segments must be consecutive.

--separator=INTEGER

Set the height of row separator bars for stacked symbologies, where INTEGER is in integral multiples of the X-dimension. The default is zero.

--small

Use a smaller font for Human Readable Text (HRT).

--square

For Data Matrix symbols, exclude rectangular sizes when considering automatic sizes. See also --dmre.

--structapp=I,C[,ID]

Set Structured Append info, where I is the 1-based index, C is the total number of symbols in the sequence, and ID, which is optional, is the identifier that all symbols in the sequence share. Structured Append is supported by Aztec Code, Code One, Data Matrix, DotCode, Grid Matrix, MaxiCode, MicroPDF417, PDF417, QR Code and Ultracode.

-t, --types

Display the table of barcode types (symbologies). The numbers or names can be used with -b | --barcode.

--textgap=NUMBER

Adjust the gap between the barcode and the Human Readable Text (HRT). NUMBER is in X-dimensions, and may be floating-point. Maximum is 10 and minimum is -5. The default is 1.

--vers=INTEGER

Set the symbol version (size, check digits, other options) to INTEGER. The meaning is symbol-specific.

For most matrix symbols, it specifies size:

Aztec Code      1 to 36 (1 to 4 compact)
        1   15x15     13  53x53     25  105x105
        2   19x19     14  57x57     26  109x109
        3   23x23     15  61x61     27  113x113
        4   27x27     16  67x67     28  117x117
        5   19x19     17  71x71     29  121x121
        6   23x23     18  75x75     30  125x125
        7   27x27     19  79x79     31  131x131
        8   31x31     20  83x83     32  135x135
        9   37x37     21  87x87     33  139x139
        10  41x41     22  91x91     34  143x143
        11  45x45     23  95x95     35  147x147
        12  49x49     24  101x101   36  151x151

Code One        1 to 10 (9 and 10 variable width) (WxH)
        1   16x18     6   70x76
        2   22x22     7   104x98
        3   28x28     8   148x134
        4   40x42     9   Wx8
        5   52x54     10  Wx16

Data Matrix     1 to 48 (31 to 48 DMRE) (HxW)
        1   10x10     17  72x72     33  8x80
        2   12x12     18  80x80     34  8x96
        3   14x14     19  88x88     35  8x120
        4   16x16     20  96x96     36  8x144
        5   18x18     21  104x104   37  12x64
        6   20x20     22  120x120   38  12x88
        7   22x22     23  132x132   39  16x64
        8   24x24     24  144x144   40  20x36
        9   26x26     25  8x18      41  20x44
        10  32x32     26  8x32      42  20x64
        11  36x36     28  12x26     43  22x48
        12  40x40     28  12x36     44  24x48
        13  44x44     29  16x36     45  24x64
        14  48x48     30  16x48     46  26x40
        15  52x52     31  8x48      47  26x48
        16  64x64     32  8x64      48  26x64

Grid Matrix     1 to 13
        1   18x18     6   78x78     11  138x138
        2   30x30     7   90x90     12  150x150
        3   42x42     8   102x102   13  162x162
        4   54x54     9   114x114
        5   66x66     10  126x126

Han Xin         1 to 84
        1   23x23     29  79x79     57  135x135
        2   25x25     30  81x81     58  137x137
        3   27x27     31  83x83     59  139x139
        4   29x29     32  85x85     60  141x141
        5   31x31     33  87x87     61  143x143
        6   33x33     34  89x89     62  145x145
        7   35x35     35  91x91     63  147x147
        8   37x37     36  93x93     64  149x149
        9   39x39     37  95x95     65  151x151
        10  41x41     38  97x97     66  153x153
        11  43x43     39  99x99     67  155x155
        12  45x45     40  101x101   68  157x157
        13  47x47     41  103x103   69  159x159
        14  49x49     42  105x105   70  161x161
        15  51x51     43  107x107   71  163x163
        16  53x53     44  109x109   72  165x165
        17  55x55     45  111x111   73  167x167
        18  57x57     46  113x113   74  169x169
        19  59x59     47  115x115   75  171x171
        20  61x61     48  117x117   76  173x173
        21  63x63     49  119x119   77  175x175
        22  65x65     50  121x121   78  177x177
        23  67x67     51  123x123   79  179x179
        24  69x69     52  125x125   80  181x181
        25  71x71     53  127x127   81  183x183
        26  73x73     54  129x129   82  185x185
        27  75x75     55  131x131   83  187x187
        28  77x77     56  133x133   84  189x189

Micro QR        1 to 4  (M1, M2, M3, M4)
        1   11x11     3   15x15
        2   13x13     4   17x17

QR Code         1 to 40
        1   21x21     15  77x77     29  133x133
        2   25x25     16  81x81     30  137x137
        3   29x29     17  85x85     31  141x141
        4   33x33     18  89x89     32  145x145
        5   37x37     19  93x93     33  149x149
        6   41x41     20  97x97     34  153x153
        7   45x45     21  101x101   35  157x157
        8   49x49     22  105x105   36  161x161
        9   53x53     23  109x109   37  165x165
        10  57x57     24  113x113   38  169x169
        11  61x61     25  117x117   39  173x173
        12  65x65     26  121x121   40  177x177
        13  69x69     27  125x125
        14  73x73     28  129x129

rMQR            1 to 38 (33 to 38 automatic width) (HxW)
        1   7x43      14  11x77     27  15x139
        2   7x59      15  11x99     28  17x43
        3   7x77      16  11x139    29  17x59
        4   7x99      17  13x27     30  17x77
        5   7x139     18  13x43     31  17x99
        6   9x43      19  13x59     32  17x139
        7   9x59      20  13x77     33  7xW
        8   9x77      21  13x99     34  9xW
        9   9x99      22  13x139    35  11xW
        10  9x139     23  15x43     36  13xW
        11  11x27     24  15x59     37  15xW
        12  11x43     25  15x77     38  17xW
        13  11x59     26  15x99

For a number of linear symbols, it specifies check character options (“hide” or “hidden” means don’t show in HRT, “visible” means do display in HRT):

C25IATA         1 or 2 (add visible or hidden check digit)
C25IND          ditto
C25INTER        ditto
C25LOGIC        ditto
C25STANDARD     ditto
Codabar         1 or 2 (add hidden or visible check digit)
Code 11         0 to 2 (2 visible check digits to none)
                0      (default 2 visible check digits)
                1      (1 visible check digit)
                2      (no check digits)
Code 39         1 or 2 (add visible or hidden check digit)
Code 93         1      (hide the default check characters)
EXCODE39        1 or 2 (add visible or hidden check digit)
LOGMARS         1 or 2 (add visible or hidden check digit)
MSI Plessey     0 to 6 (none to various visible options)
                1, 2   (mod-10, mod-10 + mod-10)
                3, 4   (mod-11 IBM, mod-11 IBM + mod-10)
                5, 6   (mod-11 NCR, mod-11 NCR + mod-10)
                +10    (hide)

For a few other symbologies, it specifies other characteristics:

Channel Code    3 to 8    (no. of channels)
DAFT            50 to 900 (permille tracker ratio)
DPD             1         (relabel)
PZN             1         (PZN7 instead of default PZN8)
Ultracode       2         (revision 2)
VIN             1         (add international prefix)
-v, --version

Display zint version.

--vwhitesp=INTEGER

Set the height of vertical whitespace above and below the barcode, where INTEGER is in integral multiples of the X-dimension.

-w, --whitesp=INTEGER

Set the width of horizontal whitespace either side of the barcode, where INTEGER is in integral multiples of the X-dimension.

--werror

Convert all warnings into errors.

EXIT STATUS

0
Success (including when given informational options -h | --help, -e | --ecinos, -t | --types, -v | --version).
1
Human Readable Text was truncated (maximum 199 bytes) (ZINT_WARN_HRT_TRUNCATED)
2
Invalid option given but overridden by Zint (ZINT_WARN_INVALID_OPTION)
3
Automatic ECI inserted by Zint (ZINT_WARN_USES_ECI)
4
Symbol created not compliant with standards (ZINT_WARN_NONCOMPLIANT)
5
Input data wrong length (ZINT_ERROR_TOO_LONG)
6
Input data incorrect (ZINT_ERROR_INVALID_DATA)
7
Input check digit incorrect (ZINT_ERROR_INVALID_CHECK)
8
Incorrect option given (ZINT_ERROR_INVALID_OPTION)
9
Internal error (should not happen) (ZINT_ERROR_ENCODING_PROBLEM)
10
Error opening output file (ZINT_ERROR_FILE_ACCESS)
11
Memory allocation (malloc) failure (ZINT_ERROR_MEMORY)
12
Error writing to output file (ZINT_ERROR_FILE_WRITE)
13
Error counterpart of warning if --werror given (ZINT_ERROR_USES_ECI)
14
Error counterpart of warning if --werror given (ZINT_ERROR_NONCOMPLIANT)
15
Error counterpart of warning if --werror given (ZINT_ERROR_HRT_TRUNCATED)

EXAMPLES

Create “out.png” (or “out.gif” if zint built without PNG support) in the current directory, as a Code 128 symbol.

zint -d 'This Text'

Create “qr.svg” in the current directory, as a QR Code symbol.

zint -b QRCode -d 'This Text' -o 'qr.svg'

Use batch mode to read from an input file “ean13nos.txt” containing a list of 13-digit GTINs, each on a separate line, to create a series of EAN-13 barcodes, formatting the output filenames to “ean001.gif”, “ean002.gif” etc. using the special character “~”.

zint -b EANX --batch -i 'ean13nos.txt' -o 'ean~~~.gif'

BUGS

Please send bug reports to https://sourceforge.net/p/zint/tickets/.

SEE ALSO

Full documention for zint (and the API libzint and the GUI zint-qt) is available from

    https://zint.org.uk/manual/

and at

    https://sourceforge.net/p/zint/docs/manual.txt

CONFORMING TO

Zint is designed to be compliant with a number of international standards, including:

ISO/IEC 24778:2008, ANSI/AIM BC12-1998, EN 798:1996, AIM ISS-X-24 (1995), ISO/IEC 15417:2007, EN 12323:2005, ISO/IEC 16388:2007, ANSI/AIM BC6-2000, ANSI/AIM BC5-1995, AIM USS Code One (1994), ISO/IEC 16022:2006, ISO/IEC 21471:2019, ISO/IEC 15420:2009, AIMD014 (v 1.63) (2008), ISO/IEC 24723:2010, ISO/IEC 24724:2011, ISO/IEC 20830:2021, ISO/IEC 16390:2007, ISO/IEC 16023:2000, ISO/IEC 24728:2006, ISO/IEC 15438:2015, ISO/IEC 18004:2015, ISO/IEC 23941:2022, AIM ITS/04-023 (2022)

Copyright © 2024 Robin Stuart. Released under GNU GPL 3.0 or later.

AUTHOR

Robin Stuart robin@zint.org.uk


  1. See the Homebrew website https://brew.sh.↩︎

  2. In Unicode contexts, BMP stands for Basic Multilingual Plane, the plane 0 codeset from U+0000 to U+D7FF and U+E000 to U+FFFF (i.e. excluding surrogates). Not to be confused with the Windows Bitmap file format BMP!↩︎

  3. The symbologies marked with an asterisk (*) in Table : Barcode Types (Symbologies) above used different names in Zint before version 2.9.0. For example, symbology 29 used the name BARCODE_RSS14. These names are now deprecated but are still recognised by Zint and will continue to be supported in future versions.↩︎

  4. The background is omitted for vector outputs EMF, EPS and SVG when --nobackground is given. For raster outputs GIF, PCX, PNG and TIF, the background’s alpha channel is set to zero (fully transparent).↩︎

  5. Shift JIS (JIS X 0201 Roman) re-maps two ASCII characters: backslash (\) to the yen sign (¥), and tilde (~) to overline (U+203E).↩︎

  6. ISO/IEC 646 Invariant is a subset of ASCII with 12 characters undefined: #, $, @, [, \, ], ^, `, {, |, }, ~.↩︎

  7. BARCODE_MEMORY_FILE textual formats EPS and SVG will have Unix newlines (LF) on both Windows and Unix, i.e. not CR+LF on Windows.↩︎

  8. The height value is ignored for Aztec (including HIBC and Aztec Rune), Code One, Data Matrix (including HIBC), DotCode, Grid Matrix, Han Xin, MaxiCode, QR Code (including HIBC, Micro QR, rMQR and UPNQR), and Ultracode - all of which have a fixed width-to-height ratio (or, in the case of Code One, a fixed height).↩︎

  9. For Windows, outfile is assumed to be UTF-8 encoded.↩︎

  10. The BARCODE_BIND_TOP flag is set by default for DPD - see 6.1.10.7 DPD Code.↩︎

  11. The BARCODE_BIND flag is always set for Codablock-F, Code 16K and Code 49. Special considerations apply to ITF-14 - see 6.1.2.6 ITF-14.↩︎

  12. Codablock-F, Code 16K, Code 49, EAN-2 to EAN-13, ISBN, ITF-14, UPC-A and UPC-E have compliant quiet zones added by default.↩︎

  13. ZINT_CAP_EANUPC was previously named ZINT_CAP_EXTENDABLE, which is still recognised.↩︎

  14. BARCODE_CODE128AB previously used the name BARCODE_CODE128B, which is still recognised.↩︎